33
8.6 PWM ALARM SETUP
8.7 SHOT VOLUME ALARM SETUP
The Shot Volume Alarm operates by observing the ratio of shots outside of the desired volume to the total number of
shots.
Example:
Alarm If
10
Bad In
100
Evaluations. This would allow 10 shots outside of the set percentages of the shot
weight setpoint for every 100 shots.
Item
Description
Ch1 PWM Alarm
(toggle)
Enables or disables the PWM alarm.
Tolerance Time
(editable)
Sets the maximum allowable time outside the recommended duty cycle percentages
before alarming.
Item
Description
Ch1 Shot Weight Alarm
(toggle)
Enables or disables the Shot Weight alarm.
Low Percentage
(editable)
Sets the minimum percentage under the shot volume allowable. This percentage is
based off the setpoint in the active recipe.
High Percentage
(editable)
Sets the maximum percentage over the shot volume allowable. This percentage is
based off the setpoint in the active recipe.
Alarm If _ Bad
(editable)
Enter the number of allowable shots outside the setpoint and error percentages set
above.
In Evaluations
(editable)
Enter the number of total shot evaluations before resetting.
Current _ Bad
(read
-
only)
Displays the number of allowable shots outside the setpoint and error percentages
set above.
In Evaluations
(read
-
only)
Displays the number of total shot evaluations before resetting.
Shot Wt Counter Reset
(Button)
Resets the counters of bad and total shots to zero.