5.

 

Insert stem assembly (5) through inlet and metering bodies                   

(6 & 16). 

6.

 

Install gasket (18) on packing screw (19). 

7.

 

If packing cup (17) was not previously removed from packing screw 

(19) apply a drop of light oil on packing cup and carefully thread 

packing screw over threads of stem sub-assembly (5). 

8.

 

If packing cup (17) was previously removed from packing screw (19), 

apply a thin coat of light oil on packing cup and insert into packing 

screw with ·flat side facing hex on packing screw. Note, packing cup 

must be installed in correct direction. Carefully screw packing screw 

with packing cup over threads of stem sub-assembly (5). 

9.

 

Thread flat side of hex stem nut (20) onto threaded end of stem 

subassembly (5) until approximately 3/16"                         of threaded 

stem projects from recessed surface of stem nut (20). 

10.

 

Assemble trigger (25), trigger guide (26), and roll pins (23 and 24) if 

previously disassembled. Roll pin (23) slot should face toward 

threaded end of trigger guide (26).                   Lubricate area where roll 

pin (23) contacts trigger guide (26) with grease. 

11.

 

Install #6 burr (22), spring (21), and end of stem sub-assembly (5) 

which has hex stem nut (20) onto trigger guide. Do not allow hex stem 

nut (20) to drift from position on stem sub-assembly (5). 

12.

 

Tighten hex stem nut (20) to trigger guide (26) using a backup wrench 

on the fiats of trigger guide (26). 

13.

 

Tighten packing screw (19) securely by wrenching on the hex of the 

inlet body (16) and the hex of packing screw (19). 

14.

 

Place body-trigger assembly (5 through 26) in left housing (2) making 

sure roll pin (24) is engaged in hole in left housing. 

15.

 

Install lock spring ring (33) in left housing (2). 

16.

 

Place trigger lock' (32) in left housing (2). 

17.

 

Install spring sub-assembly (27 through 31) in left housing (2) behind 

trigger guide (26). 

18.

 

Install right hand housing (2) and seven screws (1). Be careful not to 

over tighten screws. 

19.

 

Install valve seat (4) and cap (3) and tighten securely. 

20.

 

Lock trigger before attaching to pump. 

 

 

Содержание 23624-30L

Страница 1: ...23624 30L MeterJet Spray Gun USER GUIDE spray com MI 23624 30L...

Страница 2: ...e unit for the next dosage The MeterJet Spray Gun will accept most Spraying Systems Co spray tips for many types of applications Features of the MeterJet Spray Gun Vertical and adjustable Vernier scal...

Страница 3: ...O READ THE CHEMICAL MANUFACTURER S LABEL AND FOLLOW ALL DIRECTIONS HEED ALL THESE WARNINGS or serious and permanent injury may result 1 DO NOT aim gun at any person or any part of the body Fluids unde...

Страница 4: ...high reactionary force of this unit 3 DO impress on other people in the spraying area the importance of obeying strict safety precautions for everyone s safety 4 DO develop a habit of shutting off the...

Страница 5: ...ise dosage To adjust the metering cylinder to a desired volume 1 16 ml rotate the metering sub assembly cap 15 to a position below 16 ml on the cylinder vertical scale Next thread the metering ring to...

Страница 6: ...emoved and entire metering sub assembly thoroughly flushed with clean water after each use Failure to clean the MeterJet after each use may cause the piston to stick and render the device inoperable M...

Страница 7: ...18 and stem 5 16 If required trigger guide 26 may be removed from trigger 25 by driving out roll pin 23 17 If required roll pin 24 may be removed from trigger 25 by driving out 18 Remove metering sub...

Страница 8: ...eviously disassembled Roll pin 23 slot should face toward threaded end of trigger guide 26 Lubricate area where roll pin 23 contacts trigger guide 26 with grease 11 Install 6 burr 22 spring 21 and end...

Страница 9: ...in locked position and remove gun from supply hose 4 Remove cap 3 and valve seat 4 5 Remove seven screws 1 6 Remove right housing 2 trigger lock 22 and lock spring 23 7 Remove inlet body 5 and trigge...

Страница 10: ...19 over threads of stem 5 5 Thread flat side of hex stem nut 20 onto threaded end of stem sub assembly 5 until approximately 3 16 of threaded stem projects from recessed surface of stem nut 20 6 Insta...

Страница 11: ...11 PARTS LIST...

Страница 12: ...North Avenue and Schmale Road P O Box 7900 Wheaton IL 60187 7901 Tel 1 800 95 SPRAY Intl Tel 1 630 665 5000 Fax 1 888 95 SPRAY Intl Fax 1 630 260 0842 www spray com MI 23624 30L Spraying Systems Co 20...

Отзывы: