mini LW
mini LW
5
DESCRIPTION OF THE LUMINAIRE
Please refer to the pictures on page 2:
①
Suspension yoke
②
Knob for opening lamp cover
③
Accessory retaining clip
④
Accessory guides
⑤
Knob for focus and light beam adjustment
⑥
Handle for tilt regulation
INTRODUCTION
The luminaire you have bought conforms to 73/23/EEC,
EN 60598-1 and EN 60598-2-1 directives and
regulations.
The labels on the side of the luminaire list the following
information:
• model
• mains supply voltage (V)
• lamp wattage (W)
• protection index IP
• maximum allowed ambient temperature in °C
• maximum temperature of the body in °C
• minimum distance from flammable surface
• information to find the position 0° of the luminaire:
when the tip of the arrow points upwards
• maximum tilt angle range. These limits, imposed by
the lamp manufacturer, should not be exceeded as
they would reduce the luminaire’s useful life or lead
to its deterioration.
INSTALLATION
• The luminaires are intended for professional use only
so they have to be installed and used by qualified
technicians.
• The products are intended for indoor use:
consequently they have to be protected from humidity
and rain, if used in different conditions (IP 20)
• Do not mount the luminaire on or near a flammable
surface
• Please note carefully the notes written on the labels
of the luminaires.
• Do not forget to connect a safety rope, if required by
local country safety regulations
• The luminaires can be either suspended, or mounted
on a stand, by turning the yoke upside-down.
ELECTRICAL CONNECTIONS
Your luminaires have been designed to use low voltage
150W-24V halogen lamps.
• The
MI FN LW/CT
e
MI PC LW/CT
models have an
internal transformer and can be connected to a 220-
240V, 50-60 Hz mains power supply. The power cable
conforms to CEI regulations 20-35.
• The
MI FN LW
and
MI PC LW
models requires
the use of an external transformer; please check
it is a “safety CE tranformer” with input voltage
corresponding to the mains one, output voltage not
over 24V, continuous wattage at least 150W, and the
minimum size of the wires between the transformer
and the luminaire is 1,5 mm2 or more according to
the distance from the transformer.
Please refer to the relevant transformer instructions
about the electrical wiring and the earth of the
system.
Before and during the installation, follow the
instructions below:
• Always check the earth wiring for the line being used.
• Ensure the required voltage of the unit is the same
as the mains one for the models with internal
transformer.
• Do not use lamps other than indicated on the lamp
table (24V 150W max).
• There are no fuses inside the units, if it is necessary
they should be installed in the mains
• The luminaires
can be connected to a dimmer on
the following conditions:
- for external transformer models (MI FN LW e
MI PC LW) check if the used transformer can
work with the dimmer and that the dimmer
can work with the chosen transformer.
- for the models with internal transformer
(MI FN LW/CT and MI PC LW/CT) please check
just that the used dimmer is suitable to deal with
charges with transformers.
WARNING: replace immediately the lamp
and/or the lenses if visibly damaged,
even if still working.
WARNING: The luminaires MI FN LW/CT e MI
PC LW/CT must always be earthed