FresneLED 450 TW - PCLED 450 TW
12
(*)
LED Boost
The Boost function allows about a 20% increase in light
output, but it is exclusively compatible with the FAN
MODE function setting in AUTO mode.
(**)
Fan Mode
There are three fan control modes. The user can choose
the mode via the OPTIONS MENU.
1) AUTO mode: the fans are automatically adjusted based
on the LED temperature.
2) STANDARD mode: the fans are always kept at the
default value.
3) SILENT mode: the fans are always kept at the minimum
value.
(***)
LED Calibration
Entering this menu, the luminaire switches on with the
set calibration values.
MENU OPTIONS - LED CALIBRATION
Item
Value
Def
Description
WW1 Calib.
0..255
255
Calibration
WW2 Calib.
0..255
255
Calibration
CW1 Calib.
0..255
255
Calibration
CW2 Calib.
0..255
255
Calibration
MENU INFO
Item
Value
Description
LED TEMPERAT.
25°C
LED temperature
WARM WH TIME
Xx Hr – xx min
Warm LED life hours
COLD WH TIME
Xx Hr – xx min
Cold LED life hours
UNIT TIME
00 Hr – 00 min Unit operation time
SOFTWARE VERSION
V. ....
Release date
It displays the
software version
LOCAL POTENTIOMETER MODE
In this mode you can adjust the light intensity using
the potentiometer “DIMMER” and choose the colour
temperature through the potentiometer “CCT” according
to the following tables:
CCT
2700 3000
3200
3500
4000
5600
6500
MENU OPTIONS
Item
Value
Def
Description
LED DELAY
OFF / 30,
60...600 ms
120 ms
Delay time on LED
output. This parameter
is ignored when you
select a personality
containing the “Delay”
channel
DIMMING
CURVE
LINEAR
QUADRATIC
QUADRATIC Gamma Correction
OUT
FREQUENCY
500,
800,1000,1500...
10000,11000,
12000...
20000 Hz
1000 Hz PWM LED frequency
LED BOOST
(*)
OFF
ON
OFF
Set the maximum
(ON) or nominal
(OFF) current value.
The absolute values
can be set in the
Factory menu.
When confi rmed the
luminaire switches off
for 1 second
FAN MODE
(**)
AUTO
STANDARD
SILENT
AUTO
Selects the fans
operation mode.
For some dmx modes
this value is ignored.
See the relevant
paragraph
DISPLAY
ROTAT.
STANDARD
ROTATED
STANDARD
180° rotation of the
display. Standard =
keys to the right of
the display.
DISPLAY
STANDBY
OFF
ON
OFF
By selecting ON the
display turns off
automatically after 60
seconds of inactivity
LED CALIB.
(***)
LED calibration setup:
enter the LED CALIB
menu
DEFAULT
SET
It sets the default
for all the user
parameters
FACTORY
SETTING
Riservato al Costruttore
Factory default setting