Spot-on SRL500 Скачать руководство пользователя страница 7

 

12

      (4) Check the Y-beam in the same way. 

       

6.2 Horizontal-line Checking 

(1) Place the instrument between two walls with the distance of 30m (or two scaleplates with the distance 

of 30m).   

                                                                                                                               

                                     

     

                                     

                (2) Place the instrument according to horizontal setting and then adjust the instrument. 

                (3)Switch on the power, and then measure the middle point of the laser beam on the wall (or scaleplate): 

hA, hB and hA

, hB

                (4)

1=hA

-hA

, 2=hB

-hB

 

D-value between 

1 and 

2 ought to be less than 6mm.

 

 

13

7. Specifications 
 

Leveling Accuracy 

Horizontal:±20

 

Vertical:±20

 

Leveling Range 

±5º 

Measuring Range 

Diameter:500m(Using the laser detector) 

Spinning Speed 

0

60

120

300

600 r.p.m 

Directional-Scanning Angle 

10 º

45 º

90 º

180 º 

Slope-adjusting Range 

±5º(Bi-directional) 

Light Source 

Laser Diode, wavelength: 635nm(green:532nm   

or 520nm) 

Down Point Diode 

Accuracy:±1mm/1.5m 

Remote controlling Distance 

Approximately 20m 

Working Temperature 

-10

-- 45

(14ºF-- 113ºF) 

Power Supply 

DC 4.8-6V(4 section of NI-MH batteries or 4 section 

of NI-MH rechargeable batteries) 

Hours in continuous use 

Approximately 20 hours 

Water-proof IP 

54 

Dimension 160(L)×160(W)×185(H)mm 

Weight 2.0kg 

 

Отзывы: