
10
(Available distance: indoor: 30M;outdoor: 20M). The telecontrolling panel includes 9 keys; the indicator on the
device will wink to show the operating signal has been sent out once pressing any key.
Functions fulfilled by the remote as follows:
(1) Spinning: Operating method referring to 3.3.3
(2) Directional scanning: Operating method referring to 3.3.4
(3) Slope adjustment: Operating method referring to 3.3.5
6. Accuracey Checking
6.1 Horizontal-surface Checking
(1) Place the instrument at the point of 50m in front of wall (or set a scaleplate at the point of 50m away from
the instrument), and then adjust the level of the base approximately to aim the X1 to the wall (or scaleplate),
as depicted below:
11
(2) After switching on the power, use the laser detector measuring the h1 of X1-beam on the wall or
scaleplate.
(3) Loose the screw of the tripod ,and then turn around the instrument 180°to measure the h2 of X2-beam on
the wall or scale- plate.
D-value between h1 and h2 ought to be less than 10mm.
Содержание SRL500
Страница 2: ...2 2 Introductions 2 1 Main body 3...