background image

Model GEN1100 1500 Surge Watts / 1100 Running Watts Portable Generator 

6

 

                                                                      

 

Powerful Voltage:

 This generator produces powerful voltage, which can result in electrocution. 

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). 

• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical 
system to this generator without a qualified electrician. Such connections must isolate generator power from utility power and comply with 

local electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in 

serious injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when utility power is 

restored. 
• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs are available in-line with 

some extension cords. 

• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and 

operate it with dry hands. 
• Do not touch bare wires or outlets (receptacles). 

• Do not allow children or non-qualified persons to operate this generator. 
  

                                                                      

 

High Temperatures:

 This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees 

Fahrenheit (65 Degrees Celsius). 

• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces. 
• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation 

and before storing indoors. 

• Hot exhaust may ignite some materials. Keep flammable materials away from this generator. 

• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure. 
 
                                                                      

 

Usage:

 Misuse of this generator can damage it or shorten its life. 

• Use this generator only for its intended purpose. 

• Operate this generator only on a dry, level surface. 

• Allow this generator to run for several minutes before connecting any electrical devices. 
• Promptly turn off any malfunctioning devices and disconnect them. 

• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator. 

• Do not turn on electrical devices until after they are connected to this generator. 

• Turn off all connected electrical devices before stopping this generator. 
 

Содержание GEN1100

Страница 1: ...ve the right to change this product at any time without prior notice This manual contains important information regarding safety operation maintenance and storage of this product Before use read caref...

Страница 2: ...1500 Surge Watts 1100 Running Watts Portable Generator FEATURES 4 Stroke OHV Engine Recoil Start Automatic Low Oil Shutdown 1 120 Volt AC Outlet 1 12 Volt DC Outlet Engine Run Time 5 Hours 50 Load Eng...

Страница 3: ...The Generator 12 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15...

Страница 4: ...conditions you do not understand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury...

Страница 5: ...se this generator ONLY outdoors in non confined areas Keep at least several feet of clearance on all sides to allow proper ventilation for this generator Chemicals According to the State of California...

Страница 6: ...ds Do not touch bare wires or outlets receptacles Do not allow children or non qualified persons to operate this generator High Temperatures This generator produces heat when in operation Temperatures...

Страница 7: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 7...

Страница 8: ...del GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generat...

Страница 9: ...tts Portable Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO...

Страница 10: ...2 Volt DC Output Socket 13 Ignition Switch 14 Pilot Lamp 1 Fuel Tank Cap 2 Safety Label 3 Control Panel 4 Grounding Terminal 5 Oil Access Panel 6 Recoil Starter 7 Carburetor Choke Lever 8 Fuel Cock GE...

Страница 11: ...ine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 13 5 fluid oz 0 40 L for this Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator...

Страница 12: ...L NOTE Because gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN1100 Fuel Tank...

Страница 13: ...hat the oil filler dipstick cap is properly screwed in place when finished verifying the oil level Step 2 Verify Gas Level Before starting this generator verify that there is sufficient gasoline in th...

Страница 14: ...e engine fails to start repeat step 6 NOTE After repeated attempts to start the engine consult the troubleshooting guide before attempting again If problems persist call 1 866 460 9436 Monday Friday 8...

Страница 15: ...a total wattage less than or equal to the rated wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated runnin...

Страница 16: ...12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 1100 do not attempt to draw more than 1300 Watts from the 120 Volt outlet Draws higher than 1300 Watt...

Страница 17: ...2 Volt batteries NEVER attempt to jumpstart a car with this generator Failing to use the correct procedure can cause a battery to explode seriously injuring anyone nearby Keep heat sparks flame and sm...

Страница 18: ...Cap Clean X Spark Plug Check Clean X Fuel Tank Verify Gas Level X Clean X Figure 7 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this...

Страница 19: ...l in a sealed container and contact your local recycling center or auto garage to arrange oil disposal To add oil to the engine crankcase 1 Confirm that this generator is on a level surface 2 Unscrew...

Страница 20: ...5 If re using the spark plug use a wire brush to clean any dirt from around the spark plug base and then re gap the spark plug 6 Screw the spark plug back into place on this generator by using the in...

Страница 21: ...urn the fuel valve to the off position Disconnect the spark plug Do not obstruct any ventilation openings Do not drop or strike this generator while moving it Store this generator in a cool dry area f...

Страница 22: ...not on level surface Move generator to a level surface to prevent triggering the low oil shutdown Engine will not start Oil is low Add or replace oil Circuit breaker is off Flip circuit breaker to on...

Страница 23: ...ORTABLE GENERATOR WIRING DIAGRAM E G ENGINE ENG SW ENGINE SW ITCH B W BLACK AND WHITE SP SPARK PLUG SC AUXILIARY WINDING B BLACK G R GENERATOR DC CHARGING WINDING GR GREEN D1 D2 RECTIFIER PL PILOT LAM...

Страница 24: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 24...

Страница 25: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 25...

Страница 26: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 26...

Страница 27: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 27...

Страница 28: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 28...

Страница 29: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 29...

Страница 30: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 30...

Страница 31: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 31 GEN1100201002...

Отзывы: