background image

Model GEN1100 1500 Surge Watts / 1100 Running Watts Portable Generator 

5

 

Notice Regarding Emissions: 

Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on 

regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine 
Modifications (EM). 

 

Legal Requirements: 

Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended 
use of this generator. Consult a qualified electrician, electrical inspector, and/or the local agency having jurisdiction. Some areas require generators 

to be registered with local utility companies. Additional regulations may apply if this generator will be used at a construction site. 

 

 
 

IMPORTANT SAFETY INSTRUCTIONS 

 

 

STOP!

 

Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this 

generator, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time. 
 

  

                                                                        

 

Carbon Monoxide Gas:

 When in operation, the exhaust from this generator contains poisonous carbon monoxide gas. Carbon 

monoxide gas is both odorless and colorless AND may be present even if you do not see or smell gas. Breathing this poison gas can 
lead to headaches, dizziness, drowsiness, loss of consciousness and eventually death.
 

• Use this generator ONLY outdoors in non-confined areas. 

• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator. 

 

                                                                           

 

Chemicals:

 According to the State of California, the exhaust from this generator contains chemicals known to cause cancer, birth 

defects, or other reproductive harm. 

 

                                                                          

 

Flammable Gasoline:

 This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or 

even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline. 

• Do not operate this generator near open flame. 

• Do not smoke near this generator. 
• Always operate this generator on a firm, level surface. 

Gasoline is highly flammable and explosive. Handling fuel can result in serious injury or burns. 

• Always shut down this generator before refueling. Refuel in a well-ventilated area. Keep heat, sparks and flame away while refueling and 

away from the location where gasoline is stored. Never refuel indoors where gasoline fumes may reach flames and/or sparks. 

• Allow this generator to cool for at least 2 minutes before removing the fuel tank cap. Loosen the cap slowly to relieve pressure in the fuel tank. 
Avoid spilling fuel. 

• Do not fill the fuel tank above the upper limit line. Gasoline may expand during operation. Do not fill to the top of the tank. 

• Always check for spilled gasoline and immediately wipe it up before starting this generator. 

• Empty the fuel tank before storing or transporting this generator. 
• Always handle fuel outdoors. 

• Before transporting, turn the fuel valve to the “OFF” position and disconnect the spark plug. 
 

Содержание GEN1100

Страница 1: ...ve the right to change this product at any time without prior notice This manual contains important information regarding safety operation maintenance and storage of this product Before use read caref...

Страница 2: ...1500 Surge Watts 1100 Running Watts Portable Generator FEATURES 4 Stroke OHV Engine Recoil Start Automatic Low Oil Shutdown 1 120 Volt AC Outlet 1 12 Volt DC Outlet Engine Run Time 5 Hours 50 Load Eng...

Страница 3: ...The Generator 12 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15...

Страница 4: ...conditions you do not understand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury...

Страница 5: ...se this generator ONLY outdoors in non confined areas Keep at least several feet of clearance on all sides to allow proper ventilation for this generator Chemicals According to the State of California...

Страница 6: ...ds Do not touch bare wires or outlets receptacles Do not allow children or non qualified persons to operate this generator High Temperatures This generator produces heat when in operation Temperatures...

Страница 7: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 7...

Страница 8: ...del GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generat...

Страница 9: ...tts Portable Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO...

Страница 10: ...2 Volt DC Output Socket 13 Ignition Switch 14 Pilot Lamp 1 Fuel Tank Cap 2 Safety Label 3 Control Panel 4 Grounding Terminal 5 Oil Access Panel 6 Recoil Starter 7 Carburetor Choke Lever 8 Fuel Cock GE...

Страница 11: ...ine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 13 5 fluid oz 0 40 L for this Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator...

Страница 12: ...L NOTE Because gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN1100 Fuel Tank...

Страница 13: ...hat the oil filler dipstick cap is properly screwed in place when finished verifying the oil level Step 2 Verify Gas Level Before starting this generator verify that there is sufficient gasoline in th...

Страница 14: ...e engine fails to start repeat step 6 NOTE After repeated attempts to start the engine consult the troubleshooting guide before attempting again If problems persist call 1 866 460 9436 Monday Friday 8...

Страница 15: ...a total wattage less than or equal to the rated wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated runnin...

Страница 16: ...12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 1100 do not attempt to draw more than 1300 Watts from the 120 Volt outlet Draws higher than 1300 Watt...

Страница 17: ...2 Volt batteries NEVER attempt to jumpstart a car with this generator Failing to use the correct procedure can cause a battery to explode seriously injuring anyone nearby Keep heat sparks flame and sm...

Страница 18: ...Cap Clean X Spark Plug Check Clean X Fuel Tank Verify Gas Level X Clean X Figure 7 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this...

Страница 19: ...l in a sealed container and contact your local recycling center or auto garage to arrange oil disposal To add oil to the engine crankcase 1 Confirm that this generator is on a level surface 2 Unscrew...

Страница 20: ...5 If re using the spark plug use a wire brush to clean any dirt from around the spark plug base and then re gap the spark plug 6 Screw the spark plug back into place on this generator by using the in...

Страница 21: ...urn the fuel valve to the off position Disconnect the spark plug Do not obstruct any ventilation openings Do not drop or strike this generator while moving it Store this generator in a cool dry area f...

Страница 22: ...not on level surface Move generator to a level surface to prevent triggering the low oil shutdown Engine will not start Oil is low Add or replace oil Circuit breaker is off Flip circuit breaker to on...

Страница 23: ...ORTABLE GENERATOR WIRING DIAGRAM E G ENGINE ENG SW ENGINE SW ITCH B W BLACK AND WHITE SP SPARK PLUG SC AUXILIARY WINDING B BLACK G R GENERATOR DC CHARGING WINDING GR GREEN D1 D2 RECTIFIER PL PILOT LAM...

Страница 24: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 24...

Страница 25: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 25...

Страница 26: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 26...

Страница 27: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 27...

Страница 28: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 28...

Страница 29: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 29...

Страница 30: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 30...

Страница 31: ...Model GEN1100 1500 Surge Watts 1100 Running Watts Portable Generator 31 GEN1100201002...

Отзывы: