Troubleshooting
Model:
C575R
Malfunction item: Bad HTR signal
Circumstance: Holding to HTR and the reading is incorrect
Possible causes:
1. Bad HTR wire connection
2. Bad HTR board
Troubleshooting:
1. Check display wire connections
2. Check drive board HTR wire connection
3. Check HTR bridge board and LED indicator
4. Check HTR contact plates and wire connection
s
3-4-2
Display
board
HTR board
S
en
so
r-
R
S
en
so
r-
L
Contact plate
wiring
Drive board
HTR contact plates
HTR board
HTR board LED indicator
Indicator
Name
Description
LED1
Telemetry
Flashes to indicate incoming telemetry signal
LED2
HTR contact
Lights to indicate hands on the contact plates
LED3
HTR output
Flashes to indicate incoming HTR signal
LED4
Heart rate
signal output
Each flash indicates each heart rate output
HTR contact plate
wiring
HTR connector (drive
board)