NOTE: Failing to perform step 3 will cause the board not to display the correct time.
Examples:
If Parameter 2 was set to 5 (5 clock digits) and Parameter 5 was set to 1 (count down)
and the desired starting time is 1:30:00 (one hour, 30 minutes), the starting time would be
entered by pressing 1 – 3 – 0 – 0 – 0. If the desired starting time is 45:00 (45 minutes), the
starting time would be entered by pressing 0 – 4 – 5 – 0 – 0.
If Parameter 2 was set to 4 (4 clock digits) and Parameter 5 was set to 0 (count up) and
the desired stopping time is 15:00 (15 minutes), the stopping time would be entered by
pressing 1 – 5 – 0 – 0. If the desired stopping time is 8:30 (8 minutes, 30 seconds), the
stopping time would be entered by pressing 0 – 8 – 3 – 0.
NOTE: As shown in the examples above, when entering starting/stopping times, all digits
specified in Parameter 2 must be used, sometimes making it necessary to use leading
zeros in order to take up the “unused” digits.
To start/stop the timer:
Press the START/STOP CLOCK key.
NOTE: Restarting a stopped timing sequence continues counting from the point at which it was
stopped. It does not reset the timer and begin counting over.
To reset the time:
stop the clock by pressing the START/STOP CLOCK key
Press and hold the NEW GAME key until the display clears and resets.
TIME OF DAY OPERATION
If the unit was configured as a time of day display the following parameters must also be set to the
specified value before the timer can be used as a time of day display:
Parameter 1 must be set to “5”
Parameter 2 must be set to “4”
Parameter 3 must be set to “5”
Parameter 6 can be set to either “0” or “1”
To set the time of day:
1. Press and hold the SET CLOCK key until the display clears.