![SPM VibChecker Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/spm/vibchecker/vibchecker_user-manual_1349095024.webp)
22
Overrange warning
If a measurement is made that exceeds the instrument’s
measuring range, VibChecker will indicate an ‘Over-
range’ error and the reading will not be accepted.
Recording readings for follow-up
The VibChecker follow-up form provides space for
readings in all three directions at up to four different
measuring points, which should adequately cover most
industrial machines. Experience will soon show which of
the measuring points and directions provide the most
useful information for diagnosing a specific problem
on any particular piece of machinery.
A graph is the best way to show clearly all significant
changes of the vibration level. To keep the form simple,
draw only the graph for the most significant direction,
normally the one giving the highest readings.
Follow-up forms for copying are found on the last pages
in this manual.
VibChecker
follow-up form
Содержание VibChecker
Страница 4: ...2 ...