Component Testing Procedures
50
ON/OFF Button Test Points are on the ON/OFF Switch located behind the button. Push Buttons, Dry Time, and Water
Temp. Selector Test Points are located on the CNC Connector on the Module Board (See “Connector Locations on the
Module Board”).
Fault Codes: F08=”ON/OFF” Switch
8. Push Buttons / Dry Time & Temp. Selectors
ON/OFF Button
Test Points
Reading
ON/OFF Switch (Out)
1 to 3
INFINITY (OL)
ON/OFF Switch (Out)
1 to 5
INFINITY (OL)
ON/OFF Switch (Out)
3 to 5
0 ohms
ON/OFF Switch (Out)
2 to 4
INFINITY (OL)
ON/OFF Switch (Out)
2 to 6
INFINITY (OL)
ON/OFF Switch (Out)
4 to 6
0 ohms
ON/OFF Switch (In)
1 to 3
0 ohms
ON/OFF Switch (In)
1 to 5
INFINITY (OL)
ON/OFF Switch (In)
3 to 5
INFINITY (OL)
ON/OFF Switch (In)
2 to 4
0 ohms
ON/OFF Switch (In)
2 to 6
INFINITY (OL)
ON/OFF Switch (In)
4 to 6
INFINITY (OL)
ON/OFF Switch
Содержание WD2000S
Страница 4: ...ii ...
Страница 18: ...12 N O T E S ...
Страница 32: ...26 N O T E S ...
Страница 45: ...39 N O T E S ...
Страница 46: ...40 N O T E S ...
Страница 71: ...65 N O T E S ...
Страница 72: ... C o p y r i g h t 2 0 0 4 W e s t l a n d S a l e s C l a c k a m a s O R 9 7 0 1 5 Splendide ...