Component Testing Procedures
49
NOTE:
Test Point ‘13’ is for the Condenser Valve. The Condenser Valve is located on
ventless (Comb-o-matic) units ONLY.
Water Valve Test Points are located on the CNE Connector on the Module Board
(See “Connector Locations on the Module Board”).
Fault Codes: N/A
7. Water Valve Test
Test Points
Reading
Cold Valve
3 to 1
1000 ohms
Hot Valve
3 to 7
1000 ohms
Cold Softener
3 to 11
1000 ohms
Condenser Valve
3 to 13
1000 ohms
WD2000S
(S/N 4)
Test Points
Reading
Cold Valve
3 to 1
1000 ohms
Hot Valve
5 to 7
1000 ohms
Cold Softener
9 to 11
1000 ohms
11 9 7 5 3 1
Model WD2000S (with serial number 406XXXXX and later)