Introduction 

This document is intended to be a brief guide to the steps you need to take to set up your Bootloader. It assumes the 
Controller (UVR1611 / UVR61) is already installed and connected to the solar sensors. 

Installation Guidelines 

We have found that the most reliable long-term results are achieved when the Streambox, Bootloader and their respective 
power supplies are installed well away from daily operational areas. The problem is that the loss of the Splash Monitoring 
service is not immediately obvious, so it can be many days or weeks before someone realises that their system is not 
being updated. We are in the process of developing a mechanism to detect the loss of communication which optionally 
sends an email alert to one or more nominated recipients, but it is always prudent to minimise the risk of disruption by 
following these guidelines: 

 

If possible install the equipment and power supplies well away from daily operational areas such as someone’s 
desk or work bench. 

 

Try and secure the equipment by attaching  it to a  wall or shelf with screws, Velcro or double sided tape. This 
should prevent it from slipping and becoming disconnected. 

 

Always secure the STREAMbox power cord to the STREAMbox using the P clip supplied. The P clip should be 
located on the back of the STREAMbox using one of the existing jack posts, as illustrated: 

 

 

Always ensure the LAN cables you use are in sound condition with their retaining clips intact, and make sure they 
are securely fitted to the equipment by giving them a gentle tug. 

 

Always ensure that all cables are secured using cable ties to protect them from accidental snagging. 

 

Never stretch cables to the point where any movement could cause them to become dislodged. 

 

Always install the  STREAMbox with the ridged  heat sink outwards and the side vents unobstructed. It  doesn’t 
matter what orientation is used; horizontally on its bottom (the flat black surface); or vertically on its side. 

 

The equipment and power supplies will be labelled ‘DO NOT SWITCH OFF’, but you should inform people with 
access  to  the  installation  area  that  this  equipment  should  not  be  turned  off;  for  example  cleaning  and 
maintenance personnel. 

 

 

 