background image

4

M/S Master

N  THIS  MANUAL  A  LIGHTNING  SYMBOL  WITHIN  A  TRIANGLE  WARNS  YOU  ABOUT  THE 
POTENTIAL FOR DANGEROUS ELECTRICAL SHOCKS – WHICH CAN ALSO OCCUR EVEN AFTER 
THE MACHINE HAS BEEN DISCONNECTED FROM A POWER SOURCE.

AN  EXCLAMATION  MARK  (!)  WITHIN  A  TRIANGLE  IS  INTENDED  TO  MAKE  YOU  AWARE  OF 
IMPORTANT  OPERATIONAL  ADVICE  AND/OR  WARNINGS  THAT  MUST  BE  FOLLOWED.  BE 
ESPECIALLY ATTENTIVE TO THESE AND ALWAYS FOLLOW THE ADVICE THEY GIVE.

The symbol of a lamp directs your attention to explanations of important functions or appli-
cations.

Attention:

 Do not attempt any alterations to this machine without the approval or supervi-

sion of SPL electronics GmbH. Doing so could nullify completely any and all of your warranty/
guarantee rights and claims to user support.

The scope of delivery comprises the Frontliner, the external power supply, the guarantee card 
and this manual. 

Please  keep  the  original  packaging.  In  case  of  a  service  procedure  the  original  packaging 
ensures a safe transport. It also serves as a safe packaging for your own transports if you do 
not use special transportation cases.

Please note and retain this manual. Carefully read and follow all of the safety and operating 
instructions before you use the machine. Be doubly careful to follow all warnings and special 
safety instructions noted in this manual and on the unit. 

Connections: 

Only use the connections as described. Other connections can lead to health 

risks and equipment damage.

Water and humidity:

 Do not use this machine anywhere near water (for example near a wash 

basin or bath, in a damp cellar, near swimming pools, or the like). In such cases there is an 
extremely high risk of fatal electrical shocks!

Insertion of foreign objects or fluids: 

Never allow a foreign object through any of the machine‘s 

chassis openings. You can easily come into contact with dangerous voltage or cause a dama-
ging short circuit. Never allow any fluids to be spilled or sprayed on the machine. Such actions 
can lead to dangerous electrical shocks or fire! 

Opening the unit:

 Do not open the machine housing, as there is great risk you will damage the 

machine, or – even after being disconnected – you may receive a dangerous electrical shock!

Electrical power:

 Run this machine only from power sources which can provide proper power 

in the range from 100 to 250 volts. When in doubt about a source, contact your dealer or a 
professional electrician. To be sure you have isolated the machine, do so by disconnecting all 
power and signal connections. Be sure that the power supply plug is always accessible. When 
not using the machine for a longer period, make sure to unplug it from your wall power socket 
and from the guitar amp. 

Cord protection:

 Make sure that your power and guitar amplifier signal cords are arranged 

to avoid being stepped on or any kind of crimping and damage related to such event. Do not 
allow any equipment or furniture to crimp the cords.

Power  connection  overloads: 

Avoid  any  kind  of  overload  in  connections  to  wall  sockets, 

extension or splitter power cords, or to signal inputs. Always keep manufacturer warnings 
and instructions in mind. Overloads create fire hazards and risk of dangerous shocks!           >

Symbols and Notes

Scope of Delivery

Important Security Information

Содержание M/S Master 1020

Страница 1: ...3 2 1 0 1 2 3 4 5 6 7 8 9 1 0 1 0 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 1 0 Model 1020 M S Master LEVEL STEREO WIDTH OUTPUT L E FT 1 6 1 5 1 4 1 3 10 8 5 2 0 2 3 4 dB INSERT MUTE ACTIVE Mid Side M I...

Страница 2: ...2163 983 420 E Mail info spl info Internet spl info The construction of the MS Master Model 1020 is in compliance with the stan dards and regulations of the European Community Notes on Environmental...

Страница 3: ...9 XLR sockets Balanced connections Unbalanced connections Power connection and fuse 10 Voltage Selector Power switch GND Lift 11 Operation 11 Overview ACTIVE 11 Control Elements 12 Input settings BAL...

Страница 4: ...r example near a wash basin or bath in a damp cellar near swimming pools or the like In such cases there is an extremely high risk of fatal electrical shocks Insertion of foreign objects or fluids Nev...

Страница 5: ...ing the power cord Replacement substitute parts Be sure that any service technician uses original replacement parts or those with identical specifications as the originals Incorrectly substituted part...

Страница 6: ...me differences Due to the advantages and disadvantages that each tech nique provides more often than not they are combined during production to achieve L R play back While there are several stereo tec...

Страница 7: ...Master allows you to directly correct the balance in the mid frequency range and improve the depth and transparency of stringed instruments Thanks to the inserts you can also use filters and effects c...

Страница 8: ...TRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK D O N O T O P E N C A U T I O N For unbalanced operation connect Pin 3 to GND Pin 1 SERIAL No VOLTAGE FUSE GND LIFT GND LIFT GND 0 I Make sure that the volt...

Страница 9: ...signal flow also refer to the next chapter MID INSERT SIDE INSERT MID INSERT SIDE INSERT Both MID and SIDE channels have insert points that enable you to integrate external proces sors in each channe...

Страница 10: ...dio and reference signal Unbalanced connections Unbalanced connections from and to RCA or 1 4 TS sockets can be made without adaptors to the balanced XLR sockets The correct wiring is important The di...

Страница 11: ...adjust the balance of Mid signals in the stereo panorama and their level 2 In the SIDE section you define the stereo width and apply filters as well as other func tions to the signal 3 In the OUTPUT...

Страница 12: ...ou ought to consider minor tolerances and compensate if needed The M S Master was not conceived to provide a perfect comparison between L R and M S encoding Its primary goal is individual processing o...

Страница 13: ...d always ponder if it is more appropriate to decrease one or increase the other For example to expand the stereo image without losing mono compatibility the most convenient would be to increase the ST...

Страница 14: ...ans that the filter processes all frequencies below 2 2 kHz FILTER OFF Use this push button to disengage the filter By disengaging the filter the processing is done solely on the Side signal encoded d...

Страница 15: ...right 2 the stereo image is 200 wider As you turn the control to the left the Side signal is made smaller When set hard left the Side signal is muted Adjustment of the STEREO WIDTH should always be m...

Страница 16: ...refore provides information on the overall loudness or energy of the signal PPM mode PPM Peak Program Meter indicates peak levels similar to AD converter meters where it is important to control peak l...

Страница 17: ...a normal meter ACTIVE Use the ACTIVE push button to switch on or off the processing electronics of the M S Master When switched off input signals are forwarded directly to the outputs The ACTIVE push...

Страница 18: ...ents of finished mixes making it easier to increase overall loudness while preserving the dynamic range Let s take for example a pop song that sounds fairly balanced even though the vocals are a bit t...

Страница 19: ...ents become more precise and distinguishable Selective EQ can give the Side signal more air making cymbals and harmonic instruments sound more present without adding too much sharpness to vocals Incre...

Страница 20: ...put level and unity gain Total harmonic distortion noise 0 007 1 kHz 0 dBu input level and unity gain Signal to noise ratio A weighted 82 dB Dynamik range unweighted 102 dB Power supply Toroidal trans...

Страница 21: ...5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 1 0 1 0 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 1 0 Model 1020 M S Master L E V E L S T E R E O W I D T H O U T P U T LE F T 1 6 15 14 13 1 0 8 5 2 0 2 3 4 dB INSERT MUTE A...

Страница 22: ...Manual M S Master Model 1020...

Отзывы: