Spitwater Vacstorm M9 Скачать руководство пользователя страница 4

MAINTENANCE INSTRUCTIONS 

 
To maintain your unit in peak working condition during its operable life it is necessary to carry out regular 
maintenance operations and replace worn or broken-down parts immediately upon their failure.  We suggest 
that a qualified service person carries out all maintenance and that original replacement parts be used in 
effecting repairs to guarantee quality, reliability and longevity. 

Failure to follow the above instructions 

releases the manufacturer from any responsibility

 

in reference to injuries and damages to both 

persons and goods and may render any warranty given with the unit void.

 

Please find below a summary table of maintenance operation with a general description on how they should 
be carried out: 
 
CHECKS TO BE CARRIED OUT BY THE USER 
GENERAL 
1)  Power Cable (Each use) 

a)  Check power cable for cuts, abrasion or general damage each time the unit is used. If power cord 

plugs are damaged, they must be replaced immediately (not repaired) by an authorised service 
person / electrician.  

2)  Filter/Float/Tank (Each use) 

a)  Check that the solution filter is clean and in good condition.  
b)  Check that the float is operating correctly and in good condition. 
c)  Clean and empty both recovery and solution tanks after every use. Do not allow material / liquid to sit 

in the tanks for a prolonged period. 

3)  Performance (Each use) 

a)  Check machine functionality (ie. operation, suction etc.) and performance and make sure that 

everything operates as described in the operating instructions. Should any malfunction occur, stop 
operating the unit immediately and contact an authorised service person / agent.

 

 

4)  Filter (Every 30 Hours) 

a)  Wash solution filter using a little washing powder in lukewarm water. 

 
CHECKS TO BE PERFORMED BY AUTHORIZED SERVICE PERSON / AGENT 
Checks and the interval times at which checks that have to be performed by an authorised service person / 
agent should occur are summarised below. It is essential that such checks and repairs be carried out by an 
authorised service person / agent as they have the necessary experience and training to carry them out. 

SUMMARY OF CHECKS TO BE CARRIED 
OUT BY THE USER 

SUMMARY OF CHECKS TO BE CARRIED OUT BY 
AN AUTHORIZED SERVICE PERSON/AGENT 

Power 
cable/Filter/Float/Tank/Performance 

Each use 

Motor Brushes 

Each 250 
hours 

Filter Wash 

Each 30 
hours 

Pump 

Each 250 
hours 

 
NOTE:  
1)  The time indication for checks and replacement listed above are for units subject to normal 

operating conditions. Should the unit be subject to abnormal conditions (ie. heavy duty use, 
extreme temperatures or climatic conditions etc.) the times should be reduced accordingly 

2)  Should the unit be subject to very limited use all checks and, if necessary, replacements should 

be carried out at least once per year. 

 

 

 

 

 

 

 

 

 

Отзывы: