1.  Caution should be taken when lifting the unit. 

Always adopt safe lifting techniques in order to 
avoid damage to the unit and injuries to person. 

2.  Remove carton and carefully remove the unit 

from the pallet keeping it upright. Visually check 
for any damage, leaks or other issues. If any 
problem is found, contact your Spitwater agent 
immediately. 

3.  Identify the unit from the information on the serial 

label affixed to the unit.

 

 

4. 

Connect the wheels to the base using the supplied hub 
cap block and hub cap cover.

 

 

5.  Connect the high pressure cleaner to the power 

supply making sure that the voltage supply is as 
specified on the serial label and in the technical 
data in this manual. This unit must be earthed. 
Please note that incorrect voltage or insufficient 
power supply will cause immediate damage to the 
unit.  

 

ASSEMBLY & INSTALLATION GUIDE

 

Note: Any work needed on initial installation to 
connect the unit to the power supply must be 
carried out by a qualified electrician in 
accordance with local standards and 
regulation.

 

6.  Replace the red oil travel plug fitted on the 

pump with the yellow dipstick supplied in the 
accessories bag.

 

 

7.  Check the oil level in the pump using the 

dipstick or the sight glass on the back / side of 
the pump. Make sure the level is between 
min/max level notches on the dipstick, or is level 
with the indicator on the sight glass. If oil 
reservoir needs replenishing only use oil of a 
type as listed in the data sheet in this instruction 
manual. 

8.  The unit must be positioned on flat stable 

ground and must be in an upright position 
before operating. Do not operate on an uneven 
surface or on loose gravel. 

9. 

PLUG ASSEMBLY 

(SHW78/A ONLY)

 

 

Only a certified Electrician should carry out this task.  

 

Plug should comply with Technical data table of this 
unit. 

 

Class 1 Appliance must only be connected to an 
earthed power supply fitted with an appropriately 
sized fuse. 

 

 
 
 
 
 

 

 

Содержание SHW78

Страница 1: ...this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufacturer fro...

Страница 2: ...ccordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the ma...

Страница 3: ...ER 10 10 10 HP PUMP MODEL WS202 WS202 WS202 OIL TYPE 15W 40 15W 40 15W 40 OIL CAPACITY 1 1 1 1 1 1 L OTHER DETERGENT BOTTLE CAPACITY 10 10 10 L BURNER PRESSURE 10 10 10 BAR VALUES DETERMINED AS PER AS...

Страница 4: ...meaning is listed next to them for your attention CAUTION Hot surface Do not touch DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS WARNING This high pressure cleaner shall only be...

Страница 5: ...remove safety labels TRIGGER GUN HIGH PRESSURE HOSE HIGH PRESSURE WATER OUTLET CONNECTOR DIESEL INLET BURNER SWITCH TEMPERATURE ADJUSTMENT DUAL LANCE PRESSURE GAUGE POWER PLUG SHW78 SHW78 SONLY UNIT O...

Страница 6: ...do so DO NOT operate the unit without appropriate personal protective equipment PPE 2 ELECTRICAL CONNECTION The voltage hertz rating and number of phases on the serial label must correspond to that o...

Страница 7: ...pe 6 FIRE PREVENTION AND HOT SURFACE CAUTION Store flammable fluids in approved containers and cabinets away from sparks and heat To avoid fire be alert for leaks of flammable substances from hoses an...

Страница 8: ...ergent or oil follow instructions provided by the manufacturer and or product retailer and wash it off immediately with clean running water Wear rubber gloves to avoid personal injury during chemical...

Страница 9: ...user is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries...

Страница 10: ...Spitwater recommends the use of original accessories and spare parts available through Spitwater and its extensive dealer network Never use a nozzle size other than that specified in the technical dat...

Страница 11: ...ansporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or below 0 C contact your authorized Spitwater service agent...

Страница 12: ...Note Any work needed on initial installation to connect the unit to the power supply must be carried out by a qualified electrician in accordance with local standards and regulation 6 Replace the red...

Страница 13: ...do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 11 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quick...

Страница 14: ...agent if found Open the water supply and fill the water tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow preventer is con...

Страница 15: ...15 14 Remove the DIESEL tank cap and fill the diesel tank with clean filtered diesel ONLY USE CLEAN DIESEL IN THIS UNIT as using any other fuel will create a risk of explosion and damage to the unit...

Страница 16: ...s to expel Note If this is the first use of the unit or the unit has been left idle for an extended period of time it is advisable to run this operation with the front part of the lance disconnected i...

Страница 17: ...wise 1 If hot water is required turn the burner switch clockwise to ON position 2 Turn the temperature adjustment knob to achieve desire cleaning temperature 3 After hot water use turn burner switch i...

Страница 18: ...with detergent will be sprayed 4 Never allow sprayed detergent to dry on the cleaning surface as this may damage the surface TO STOP 1 Make sure burner switch is in OFF position 2 Press the OFF power...

Страница 19: ...s that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater service...

Страница 20: ...appearance Check for any service due based on USAGE VS SERVICE FREQUENCY Table A Proper function of burner switch temperature controller and pressure gauge Check for water leaks at high pressure hose...

Страница 21: ...y Time interval for checks and replacement listed above are for units subjected to normal operating conditions Should the unit be subjected to abnormal conditions e g heavy use dirty water extreme tem...

Страница 22: ...he oil level in the pump using the dipstick or the sight glass on the back side of the pump Make sure the level is between min max level notches on the dipstick or is level with the indicator on the s...

Страница 23: ...off is activated Check that water diesel tank are full and add water diesel as necessary No power supply Contact an authorized electrician to check power supply When switch is activated the motor hum...

Отзывы: