12
1. Caution should be taken when lifting the unit.
Always adopt safe lifting techniques in order to
avoid damage to the unit and injuries to person.
2. Remove carton and carefully remove the unit
from the pallet keeping it upright. Visually check
for any damage, leaks or other issues. If any
problem is found, contact your Spitwater agent
immediately.
3. Identify the unit from the information on the serial
label affixed to the unit.
4.
Connect the wheels to the base using the supplied hub
cap block and hub cap cover.
5. Connect the high pressure cleaner to the power
supply making sure that the voltage supply is as
specified on the serial label and in the technical
data in this manual. This unit must be earthed.
Please note that incorrect voltage or insufficient
power supply will cause immediate damage to the
unit.
ASSEMBLY & INSTALLATION GUIDE
Note: Any work needed on initial installation to
connect the unit to the power supply must be
carried out by a qualified electrician in
accordance with local standards and
regulation.
6. Replace the red oil travel plug fitted on the
pump with the yellow dipstick supplied in the
accessories bag.
7. Check the oil level in the pump using the
dipstick or the sight glass on the back / side of
the pump. Make sure the level is between
min/max level notches on the dipstick, or is level
with the indicator on the sight glass. If oil
reservoir needs replenishing only use oil of a
type as listed in the data sheet in this instruction
manual.
8. The unit must be positioned on flat stable
ground and must be in an upright position
before operating. Do not operate on an uneven
surface or on loose gravel.
9.
PLUG ASSEMBLY
(SHW78/A ONLY)
•
Only a certified Electrician should carry out this task.
•
Plug should comply with Technical data table of this
unit.
•
Class 1 Appliance must only be connected to an
earthed power supply fitted with an appropriately
sized fuse.