1.  Fill the detergent tank with cleaning solution. Only 

use a cleaning detergent approved by the 
manufacturer and do not use under any 
circumstance acid or corrosive products (contact an 
authorized service agent or the manufacturer if in 
doubt). 

 

2.  If detergent is required it 

CAN BE USED IN LOW 

PRESSURE ONLY

. To activate low pressure turn 

the lance handle anti-clockwise and pull the trigger. 
Turn back the handle clockwise to switch OFF low 
pressure and chemical. 

 

3.  Open the chemical injector by turning the knob 

anti-clockwise until the desired affect is reached. 
When the trigger is pulled, water mixed with 
detergent will be sprayed.

 

 

4.  Never allow sprayed detergent to dry on the 

cleaning surface, as this may damage the 
surface. 

TO STOP 

1.  Make sure burner switch is in OFF position. 

2.  Turn the unit switch to the OFF (0) position. 

 

3.  Release all trapped water pressure in the unit 

by pulling the trigger of the spray gun, then 
engage the spray gun trigger lock. Failure to 
follow this instruction will leave the unit in a 
potentially unsafe manner. 

 

4.  If  the  unit  is  to  be  left  unused  for  an  extended 

period,  be  sure  to  clean  the  detergent  line  by 
running  the  water  through  it  and  dropping  the 
detergent line into a container of clean water.

USING CLEANING AGENT   

Содержание 10-120H

Страница 1: ...rstand this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufactu...

Страница 2: ...ccordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the ma...

Страница 3: ...P PUMP MODEL WW186 WW95 N A N A N A OIL TYPE 15W 40 15W 40 OIL CAPACITY 0 4 0 3 L OTHER DETERGENT BOTTLE CAPACITY 1 5 N A L BURNER PRESSURE 9 9 BAR VALUES DETERMINED AS PER AS NZS 60335 2 79 SOUND PRE...

Страница 4: ...meaning is listed next to them for your attention CAUTION Hot surface Do not touch DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS WARNING This high pressure cleaner shall only be...

Страница 5: ...lter or remove safety labels TRIGGER GUN HIGH PRESSURE HOSE HIGH PRESSURE WATER OUTLET CONNECTOR DIESEL INLET BURNER SWITCH TEMPERATURE ADJUSTMENT DUAL LANCE PRESSURE GAUGE POWER PLUG UNIT ON OFF SWIT...

Страница 6: ...do so DO NOT operate the unit without appropriate personal protective equipment PPE 2 ELECTRICAL CONNECTION The voltage hertz rating and number of phases on the serial label must correspond to that o...

Страница 7: ...pe 6 FIRE PREVENTION AND HOT SURFACE CAUTION Store flammable fluids in approved containers and cabinets away from sparks and heat To avoid fire be alert for leaks of flammable substances from hoses an...

Страница 8: ...ergent or oil follow instructions provided by the manufacturer and or product retailer and wash it off immediately with clean running water Wear rubber gloves to avoid personal injury during chemical...

Страница 9: ...user is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries...

Страница 10: ...are parts that were not designed for use with this unit as this could cause damage to the unit Spitwater recommends the use of original accessories and spare parts available through Spitwater and its...

Страница 11: ...ansporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or below 0 C contact your authorized Spitwater service agent...

Страница 12: ...e note that incorrect voltage or insufficient power supply will cause immediate damage to the unit ASSEMBLY INSTALLATION GUIDE Note Any work needed on initial installation to connect the unit to the p...

Страница 13: ...do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 9 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quick r...

Страница 14: ...agent if found Open the water supply and fill the water tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow preventer is con...

Страница 15: ...15 12 Remove the DIESEL tank cap and fill the diesel tank with clean filtered diesel ONLY USE CLEAN DIESEL IN THIS UNIT as using any other fuel will create a risk of explosion and damage to the unit...

Страница 16: ...to expel Note If this is the first use of the unit or the unit has been left idle for an extended period of time it is advisable to run this operation with the front part of the lance disconnected in...

Страница 17: ...temperature 3 After hot water use turn burner switch in anti clockwise to turn OFF the hot water and change back to cold water mode for cleaning 1 To activate high pressure turn the lance handle clock...

Страница 18: ...until the desired affect is reached When the trigger is pulled water mixed with detergent will be sprayed 4 Never allow sprayed detergent to dry on the cleaning surface as this may damage the surface...

Страница 19: ...ents that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater servi...

Страница 20: ...appearance Check for any service due based on USAGE VS SERVICE FREQUENCY Table A Proper function of burner switch temperature controller and pressure gauge Check for water leaks at high pressure hose...

Страница 21: ...r units subjected to normal operating conditions Should the unit be subjected to abnormal conditions e g heavy use dirty water extreme temperatures or conditions etc times should be reduced accordingl...

Страница 22: ...he oil level in the pump using the dipstick or the sight glass on the back side of the pump Make sure the level is between min max level notches on the dipstick or is level with the indicator on the s...

Страница 23: ...off is activated Check that water diesel tank are full and add water diesel as necessary No power supply Contact an authorized electrician to check power supply When switch is activated the motor hum...