Steam/Water Mixing Stations (MkII valves - 2002 onwards) Safety and Operation
Fig. 16
1.
Isolate the steam and cold water supplies by closing the
two ball valves.
2.
Discharge contents of the hose and station by pulling the
gun trigger and eliminate pressure until water flow stops.
5.5 Hose
The hose should be inspected before use for evidence of wear. If there are breaks in the external
surface of the hose, it must be replaced immediately.
Note: hoses should be replaced after 12 months service. This is due to natural degradation of
rubber under hot water working conditions.
5.6 Swivel coupling
Please read in conjunction with Steps 1 to 10. Procedure for replacing swivel coupling.
Swivel coupling maintenance
Important - Inspection of internal seals:
-
The swivel coupling should be periodically inspected e.g. during routine maintenance
procedures, for evidence of wear on the internal seals. During normal usage, the swivel
action of the coupling acts upon these seals and a slight leakage may occur if the seals
are allowed to wear excessively. Under normal operating conditions the seals should be
replaced every two years.
-
Separate the hose tail from the gun retaining nut by unscrewing the hose tail using 1
5/16
" A/F
and
7/8
" A/F spanners.
-
Remove the circlip from the swivel cylinder and push the cylinder out from the retaining nut.
-
Check the two seals around the swivel cylinder for wear. If required, remove the seals e.g.
by cutting with a sharp knife. Roll the new seals onto the cylinder and into the two seal
grooves.
Do not
attempt to roll the seals over the threaded section of the cylinder, as this
may cause damage to the new seals.
-
Push the cylinder back into the retaining nut and secure with the circlip.