Spirax Sarco IBP21 Скачать руководство пользователя страница 3

IM-F01-30 

 ST Issue 5

3

1.2 Access

Ensure safe access and if necessary a safe working platform (suitably guarded) 

before attempting to work on the product. Arrange suitable lifting gear if required.

1.3 Lighting

Ensure adequate lighting, particularly where detailed or intricate work is required.

1.4 Hazardous liquids or gases in the pipeline

Consider what is in the pipeline or what may have been in the pipeline at some 

previous time. Consider: flammable materials, substances hazardous to health, 

extremes of temperature.

1.5 Hazardous environment around the product

Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, 

extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive 

noise, moving machinery.

1.6 The system

Consider the effect on the complete system of the work proposed. Will any 

proposed action (e.g. closing isolation valves, electrical isolation) put any other 

part of the system or any personnel at risk? 

Dangers might include isolation of vents or protective devices or the rendering 

ineffective of controls or alarms. Ensure isolation valves are turned on and off in 

a gradual way to avoid system shocks.

1.7 Pressure systems

 

Ensure that any pressure is isolated and safely vented to atmospheric pressure. 

Consider double isolation (double block and bleed) and the locking or labelling of 

closed valves. Do not assume that the system has depressurised even when the 

pressure gauge indicates zero.

1.8 Temperature

Allow time for temperature to normalise after isolation to avoid danger of burns 

and consider whether protective clothing (including safety glasses) is required.

The FTS14 is fitted with a viton seal and must not be subjected to temperatures 

above 315 °C (599 °F). Above this temperature toxic fumes may be given off. Avoid 

inhilation of fumes or skin contact. 

1.9 Tools and consumables

Before starting work ensure that you have suitable tools and/or consumables 

available. Use only genuine Spirax Sarco replacement parts.

1.10 Protective clothing

Consider whether you and/or others in the vicinity require any protective clothing 

to protect against the hazards of, for example, chemicals, high/low temperature, 

radiation, noise, falling objects, and dangers to eyes and face.

Содержание IBP21

Страница 1: ...nformation 3 Installation 4 Maintenance 5 Spare parts Copyright 2016 Printed in GB IM F01 30 ST Issue 5 6140050 5 ITD32 IBP21 IBP21S IBP30 ISM21 and IFT14 Steam Traps with Integral Spiratec Sensors In...

Страница 2: ...20 SEP SEP IBP21 ISM21 DN15 DN20 SEP SEP i The products have been specifically designed for use on steam air or water condensate which are in Group 2 of the above mentioned Pressure Equipment Directiv...

Страница 3: ...evices or the rendering ineffective of controls or alarms Ensure isolation valves are turned on and off in a gradual way to avoid system shocks 1 7 Pressure systems Ensure that any pressure is isolate...

Страница 4: ...each temperatures in excess of 250 C 482 F Many products are not self draining Take due care when dismantling or removing the product from an installation refer to Maintenance instructions 1 14 Freezi...

Страница 5: ...integral sensor high capacity ITD32LA with integral sensor low capacity and anti air binding disc ITD32HA with integral sensor high capacity and anti air binding disc IBP21 Steel balanced pressure typ...

Страница 6: ...IM F01 30 ST Issue 5 6 IBP21 and IBP21S ITD32 IBP30 ISM21 IFT14...

Страница 7: ...aximum operating temperature 240 464 240 464 240 464 240 464 Designed for a maximum cold hydraulic test pressure of 95 1377 38 551 38 551 60 870 For further details see TI P614 01 TI P617 01 TI P617 0...

Страница 8: ...times When welding IBP21 IBP21S IBP30 and ISM21 traps into the pipeline there is no need to remove the element capsule providing the welding is done by the electric arc method Note The trap is supplie...

Страница 9: ...he element assembly can be removed by undoing the seat Refit new capsule and spacer plate and then replace clip or complete new element Ensure that the flat screen is located centrally Fit new cover g...

Страница 10: ...BP30 Table 1 Recommended tightening torques Item Part or mm N m lbf ft 3 17 50 55 37 40 9 IBP21 ISM21 13 M8 x 35 18 22 13 16 IBP21S M10 x 30 18 22 13 16 IBP30 M10 x 42 20 27 15 20 10 IBP21 IBP21S ISM2...

Страница 11: ...Clean or replace the screen as required Replace the screen and sensor assembly ensuring that the screen is located centrally Fit new gasket and ensure that the joint faces are clean A fine smear of M...

Страница 12: ...fit new capsule and clip Align complete air vent horizontally so that the frame clears the cover Refit cover using new gasket and retighten cover bolts evenly to the recommended tightening torque How...

Страница 13: ...vailable spares for the ITD32 range The following options are available ITD32L with integral sensor low capacity ITD32H with integral sensor high capacity ITD32A with integral sensor low capacity and...

Страница 14: ...S IBP30 ISM21 Capsule and seat assembly set state capsule filling 2 3 14 2 3 14 Element set 2 3 4 Strainer screen flat 3 off 6 6 Y type strainer screen cylindrical 1 off 5 5 5 Set of cover gaskets 3 o...

Страница 15: ...e parts are available as indicated below No other parts are supplied as spares Main valve assembly with float 3 5 6 7 2 off 8 10 11 Air vent assembly 3 6 9 Cover gasket packet of 3 3 Sensor and sensor...

Страница 16: ...IM F01 30 ST Issue 5 16...

Отзывы: