3

3.797.5275.200

1.5  Hazardous environment around the product

Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of 

temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery.

1.6  The system

Consider  the  effect  on  the  complete  system  of  the  work  proposed.  Will  any  proposed  action 

(e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel 

at risk?

Dangers might include isolation of vents or protective devices or the rendering ineffective of controls 

or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks.

1.7  Pressure systems

Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double 

isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that 

the system has depressurised even when the pressure gauge indicates zero.

1.8 Temperature

Allow time for temperature to normalise after isolation to avoid danger of burns and consider whether 

protective clothing (inlcuding safety glasses) is required.

1.9  Tools and consumables

Before starting work ensure that you have suitable tools and/or consumables available. Use only 

genuine Spirax Sarco replacement parts.

1.10  Protective clothing

Consider whether you and/or others in the vicinity require any protective clothing to protect against 

the hazards of, for example, chemicals, high/low temperature, radiation, noise, falling objects, and 

dangers to eyes and face.

1.11  Permits to work

All work must be carried out or be supervised by a suitably competent person. Installation and 

operating personnel should be trained in the correct use of the product according to the Installation 

and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied 

with. Where there is no such system, it is recommended that a responsible person should know what 

work is going on and, where necessary, arrange to have an assistant whose primary responsibility 

is safety. Post 'warning notices' if necessary.

1.12 Handling

Manual handling of large and/or heavy products may present a risk of injury. Lifting, pushing, pulling, 

carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised 

to assess the risks taking into account the task, the individual, the load and the working environment 

and use the appropriate handling method depending on the circumstances of the work being done.

Содержание Colima FLU Series

Страница 1: ...I N A B I L I T Y 3 797 5275 200 CH Issue 2 2016 Copyright 2013 Vane Flow Switches Colima FLU Series Installation and Maintenance Instructions 1 General safety information 2 General product informatio...

Страница 2: ...ty of the product for the application being considered ii Check material suitability pressure and temperature and their maximum and minimum values If the maximum operating limits of the product are lo...

Страница 3: ...fore starting work ensure that you have suitable tools and or consumables available Use only genuine Spirax Sarco replacement parts 1 10 Protective clothing Consider whether you and or others in the v...

Страница 4: ...For any safety requirements relating to particular components and or materials used in the product construction please refer to installation and maintenance instructions below 1 16 Disposal This prod...

Страница 5: ...low through heating coil fails 2 1 2 Operating principle Two oscillating magnets on the same axis one integral with the vane and one integral with the elec trical equipment repel each other reciprocal...

Страница 6: ...art Material 1 Housing ALU Rilsan 2 Cover ALU Rilsan 3 Indicator Plexiglass 4 Microswicth Omron Z 15GW4 B 5 Screw AISI 304 6 Magnet Sm Co 7 Flange AISI 304 8 Magnet Sm Co 9 Counter weight AISI 304 10...

Страница 7: ...A Maximum allowable pressure Steel Colima s flange 16 bar g flange sized according to rating 100 bar g 2 4 Models FLU A Gas flow switch with IP 67 aluminum housing Can not be fitted directly on the pi...

Страница 8: ...tighten the instrument and place it in the direction indicated by the arrow on the housing base Caution Always ensure that correct earthing of the equipment is carried out Specific points are set insi...

Страница 9: ...nce 15 mOhm Max Initial value Mechanical life 106 Electrical life 105 V A Load 250 15 0 25 Resistive 15 0 03 Inductive 125 15 0 5 Resistive 15 0 05 Inductive 30 NA 6 Resistive NA 5 Inductive SPDT exec...

Страница 10: ...nstrument does not require preventive maintenance however it is recommended that from time to time a check of the liquid fluidity is actioned to avoid any suspensions or deposits that can influence we...

Страница 11: ...iption given in the column headed Available spares and state the size and serial number of the unit which is indicated on the name plate Example N 1 off Contact for flow switch for Spirax Sarco Colima...

Страница 12: ...Assistance Via per Cinisello 18 20834 Nova Milanese MB Italy Tel 39 0362 4917 257 39 0362 4917 211 Fax 39 0362 4917 315 E mail support it spiraxsarco com LOSS OF GUARANTEE Total or partial disregard o...

Отзывы: