1.4  Hazardous liquids or gases in the pipeline

Consider what is in the pipeline or what may have been in the pipeline at some 

previous time. Consider: flammable materials, substances hazardous to health, 

extremes of temperature.

1.5  Hazardous environment around the product

Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, 

extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive 

noise, moving machinery.

1.6  The system

Consider the effect on the complete system of the work proposed. Will any proposed 

action (e.g. closing isolation valves, electrical isolation) put any other part of the 

system or any personnel at risk? 

Dangers might include isolation of vents or protective devices or the rendering 

ineffective of controls or alarms. Ensure isolation valves are turned on and off in a 

gradual way to avoid system shocks.

1.7  Pressure systems 

Ensure that any pressure is isolated and safely vented to atmospheric pressure. 

Consider double isolation (double block and bleed) and the locking or labelling of 

closed valves. Do not assume that the system has depressurised even when the 

pressure gauge indicates zero.

1.8 Temperature

Allow time for temperature to normalise after isolation to avoid danger of burns.

Viton - CA44 and CA46 main valve cone:

If the the main valve cone (made of Viton) has been subjected to a temperature 

approaching 315°C (599°F) or higher it may have decomposed and formed hydrofluoric 

acid. Avoid skin contact and inhalation of any fumes as the acid will cause deep skin 

burns and damage the respiratory system.

1.9  Tools and consumables

Before starting work ensure that you have suitable tools and / or consumables 

available. Use only genuine Spirax Sarco replacement parts.

1.10  Protective clothing

Consider whether you and / or others in the vicinity require any protective clothing          

to protect against the hazards of, for example, chemicals, high / low temperature, 

radiation, noise, falling objects, and dangers to eyes and face.

1.11  Permits to work

All work must be carried out or be supervised by a suitably competent person.

Installation and operating personnel should be trained in the correct use of the 

product according to the Installation and Maintenance Instructions.

Where a formal 'permit to work' system is in force it must be complied with. Where 

there is no such system, it is recommended that a responsible person should know 

what work is going on and, where necessary, arrange to have an assistant whose 

primary responsibility is safety.

Post 'warning notices' if necessary.

Содержание CA44

Страница 1: ...General product information 3 Installation 4 Commissioning 5 Operation 6 Maintenance 7 Spare parts Copyright 2015 Printed in GB CA44 CA44S CA46 and CA46S Air and Gas Traps Installation and Maintenanc...

Страница 2: ...e on other fluids may be possible but if this is contemplated Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered ii Check material suitabil...

Страница 3: ...8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns Viton CA44 and CA46 main valve cone If the the main valve cone made of Viton has been subjected to a tem...

Страница 4: ...age in environments where they may be exposed to temperatures below freezing point 1 15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions this product is recyclable and...

Страница 5: ...soft valve cone and has horizontal flanged connections The cover will be drilled and tapped BSP or NPT for the purpose of fitting a balance line Body and cover castings are produced by a T V approved...

Страница 6: ...ed PN and JIS KS flanges will be provided with BSP balance line and ASME flanges with an NPT balance line Limiting conditions Maximum body design conditions PN40 PMA Maximum allowable pressure 40 bar...

Страница 7: ...ferential pressure bar psi CA44 32 32 0 464 00 32 0 464 00 29 0 420 50 20 0 290 00 12 0 174 00 CA44S 4 5 4 5 65 25 4 5 65 25 4 5 65 25 3 4 49 30 2 0 29 00 CA44S 10 10 0 145 00 9 5 137 75 6 8 98 60 5 5...

Страница 8: ...nditions Maximum body design conditions PN40 PMA Maximum allowable pressure 40 bar g 580 psi g TMA Maximum allowable temperature 400 C 752 F PMO Maximum operating pressure 40 bar g 580 psi g TMO Maxim...

Страница 9: ...150 DN40 and DN50 only PMX Maximum differential pressure Depending on the specific gravity of the liquid being drained Specific gravity Trap 1 0 0 9 0 8 0 7 0 6 Maximum differential pressure bar psi...

Страница 10: ...ssure and temperature and their maximum values If the maximum operating limit of the product is lower than that of the system in which it is being fitted ensure that a safety device is included in the...

Страница 11: ...IM P148 37 ST Issue 3 11 Fig 5 Installation with balance line arrangement Balance line CA14 air trap draining small receiver Air receiver Strainer...

Страница 12: ...Tighten the assembly set screws 7 to the recommended torque see Table 1 Check the operation by raising and lowering the float 8 several times making sure that the valve head is centering properly on t...

Страница 13: ...x 20 2 5 2 8 1 8 2 1 19 DN40 10 A F M6 x 20 10 12 7 9 DN50 13 A F M8 x 20 20 24 15 17 Fig 6 CA44S and CA46S DN40 and DN50 Note The trap shown is the DN40 and DN50 CA44S CA46S However the type of inte...

Страница 14: ...The CA44 and CA46 use a soft Viton valve head where as the CA44S and CA46S use a stainless steel valve head Note The trap shown is the DN40 and DN50 CA44S CA46S However the type of internals and the...

Страница 15: ...IM P148 37 ST Issue 3 15 Fig 7 CA44S and CA46S DN40 and 50 see note under Available spares 3 6 16 5 15 14 7 8 Main valve assembly with float 9 DN40 and 50 CA44S and CA46S only CA44 and CA46 only...

Страница 16: ...IM P148 37 ST Issue 3 16...

Отзывы: