1. General safety information

Safe operation of the unit can only be guaranteed if it is properly installed,
commissioned and maintained by a qualified person (see Section 11 of the attached
Supplementary Safety Information) in compliance with the operating instructions.
General installation and safety instructions for pipeline and plant construction, as
well as the proper use of tools and safety equipment must also be complied with.

Isolation

Consider whether closing isolating valves will put any other part of the system or
personnel at risk. Dangers might include; isolation of vents and protective devices or
alarms. Ensure isolation valves are turned off in a gradual way to avoid system shocks.

Pressure

Before attempting any maintenance consider what is or may have been in the pipeline.
Ensure that any pressure is isolated and safely vented to atmospheric pressure before
attempting to maintain the product, this is easily achieved by fitting Spirax Sarco
depressurisation valves type DV (see separate literature for details). Do not assume
that the system is depressurised even when a pressure gauge indicates zero.

Temperature

Allow time for temperature to normalise after isolation to avoid the danger of burns and
consider whether protective clothing (including safety glasses) is required.

Viton 'O' ring:

If the Viton 'O' ring has been subjected to a temperature approaching 315°C (599°F) or
higher, it may have decomposed and formed hydrofluoric acid. Avoid skin contact and
inhalation of any fumes as the acid will cause deep skin burns and damage the respiratory
system.

Disposal

The product is recyclable. No ecological hazard is anticipated with the disposal of this
product providing due care is taken, EXCEPT:

Viton:

-

Waste parts can be landfilled, when in compliance with National and Local regulations.

-

Waste parts can be incinerated, but a scrubber must be used to remove Hydrogen
Fluoride, which is evolved from the product and with compliance to National and
Local regulations.

-

Is insoluble in aquatic media.

Содержание AE36

Страница 1: ...ir Vents for Liquid Systems Installation and Maintenance Instructions IM P017 03 ST Issue 5 0170550 5 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operat...

Страница 2: ...maintain the product this is easily achieved by fitting Spirax Sarco depressurisation valves type DV see separate literature for details Do not assume that the system is depressurised even when a pres...

Страница 3: ...water installations The body and cap are of austenitic stainless steel type 316L They are available as follows AE36 Standard air vent AE36A Standard air vent with check valve Note For further informat...

Страница 4: ...owable pressure 10 bar g 150 C 145 psi g 302 F TMA Maximum allowable temperature 150 C 302 F Minimum allowable temperature 10 C 14 F PMO Maximum operating pressure 10 bar g 110 C 145 psi g 230 F TMO M...

Страница 5: ...in the system to prevent overpressurisation 3 2 Determine the correct installation situation and the direction of fluid flow 3 3 Remove protective covers from all connections 3 4 Theautomaticairelimin...

Страница 6: ...lever and the whole assembly screwed back into the body see Table 1 for recommended tightening torques The set of internals are supplied with a check valve ball and circlip The check valve is only re...

Страница 7: ...IM P017 03 ST Issue 5 7 Table 1 Recommended tightening torques or Item N m lbf ft mm 1 30 10 12 7 0 8 6 8 Cheesehead M4 x 6 2 5 2 8 1 8 2 0 Fig 4 1 8 4 5 AE36A only...

Страница 8: ...earlier versions of the AE36 designated AE36CV which operate over the range 3 to 8 bar then the spares set for the AE36A cannot be used The earlier spares set should be used How to order spares Alway...

Отзывы: