SC30MPA: 3 Mega Pixels Serial JPEG Camera User Manual
Spinel USA LLC
www.spinelelectronics.com
5
56 00 31 05
05
01 00 19
44
(
1280*720
)
RETURN
:
76 00 31 00 00 //
image size is around
105kb
56 00 31 05
05
01 00 19
55
(
1280*960
)
RETURN
:
76 00 31 00 00 //
image size is around
127kb
56 00 31 05
05
01 00 19
77
(
1600*1200
)
RETURN
:
76 00 31 00 00 //
image size is around
176kb
56 00 31 05
05
01 00 19
66
(
1920*1080
)
RETURN
:
76 00 31 00 00 //
image size is around
192kb
56 00 31 05
05
01 00 19
88
(
2304*1296
)
RETURN
:
76 00 31 00 00 //
image size is around
256kb
Note:
after setting the desired image size, wait for 3 seconds and then the new setting would be
saved in flash. The actual file size is subject to the field complexity and depth of field.
9. CHANGE DEFAULT BAUD RATE: 56 00 31 06
04
02 00 08
XX YY
RETURN
:
76 00 31 00 00
XX YY ----- BAUD RATE
56 00 31 06
04
02 00 08 AE C8 AE C8 9600
56 00 31 06
04
02 00 08 AE C8 56 E4 19200
56 00 31 06
04
02 00 08 AE C8 2A F2 38400
56 00 31 06
04
02 00 08 AE C8 1C 4C 57600
56 00 31 06
04
02 00 08 AE C8 0D A6 115200 (
default & Max for RS485
)
56 00 31 06
05
02 00 08 EE A1 EE A1 230400 (Max for RS232)
56 00 31 06
05
02 00 08 EE A1 EE A2 460800 (for TTL only)
56 00 31 06
05
02 00 08 EE A1 EE A3 921600 (for TTL only and Max)
Note:
After any change, it’s not required to reset the camera, the new change will be valid and saved
in flash after power-off.
Warning: Please do not try to issue the commands on RS485 interfaced cameras for baud rates
over 115200bps, it will damage the camera immediately and the camera needs to be returned
to Spinel for repair at client’s cost.