When installing the device, please make sure that the motor is sufficiently ventilated. 

 

5.2. 

Installation of the suction line 

  

 

5.

Stationary installation 

 

 

With regard to the electrical connection in the case of stationary installation, please ensure an 

adequate visibility and accessibility of the plug. 

 For stationary installation, please fasten the pump on a suitable, solid surface. To reduce vibration, it is 

recommended to apply an anti-vibration material - for instance a rubble layer - between the pump and the 

installation surface. 

 

 

 

 

 

 

5.

Using the pump for garden ponds and similar places 

 

 

Operating the pump next to garden ponds and similar places is generally only admissible if no 

persons are in contact with the water. 

 If the pump is used for garden ponds and similar places it has to be operated using a residual current circuit-

breaker (FI switch) with a nominal trigger current of 

≤ 30mA (DIN VDE 0100

-702 and 0100-738). Please ask your 

electrical services provider whether your installation site complies with this condition. 

10

The suction line (2) will convey the pumped fluid to the pump. Please screw one of the connection pieces together 

with one of the sealing rings to the check valve (3) and intake filter (4) assembly. Insert the other end of the 

connection piece as far as possible into the suction line, then use a hose clamp to fasten it in this position. In the 

same way, insert another connection into the other end of the suction line and fasten it there using an additional 

hose clamp. Fill the suction line completely with the pumped fluid. Subsequently, please screw the fluid-filled 

suction line together with one sealing ring onto the suction port of the pump. 

 

.3. 

Venting the pump housing 

 

Please remove the closure (10) from the venting port (9) located on top of the pump housing. Subsequently, fill 

the pump housing completely with pumping fluid through the pressure port (5) of the pump. The pump housing is 

fully vented as soon as the liquid to be discharged has mounted up to the edge of the open venting port. 

Subsequently, please close the venting opening again. 

 

.4. 

Installing the pressure line 

 The pressure line (11) will convey the fluid being pumped from the pump to the point of withdrawal. Slide the fuel 

nozzle (6) onto the pressure line, then fasten it in place using one of the hose clamps. Continue by inserting one 

connection piece fully into the other end of the pressure line, and fasten it in that position using another hose 

clamp. Finally, screw the pressure line together with one sealing ring onto the pressure port (5) of the pump. 

 

When handling diesel fuel or fuel oil, smoking is not allowed, and open fire is to be kept off the 

site. Please avoid inhaling the vapours. Ensure sufficient ventilation. Please wipe off any 

spilled diesel fuel, fuel oil or rapeseed oil completely. 

 

All connection lines have to be perfectly tight since leaking lines will affect the performance of the pump and may 

even cause considerable damage. Please use appropriate sealing material to ensure an airtight installation. The 

use of 

37)(

 tape or comparable sealing material is to be avoided since it will be destroyed by diesel fuel, fuel oil 

and rapeseed oil. 

When tightening threaded connections, please do not apply excessive force which may cause damage. When 

laying the connection pipes, you should make sure that the pump is not exposed to any form of weight, vibration 

or tension. Moreover, the connection lines must not contain any kinks or an adverse slope. 
The scope of delivery includes one intake line (2) and one pressure line (11) which were specifically designed for 

the type of fluid to be discharged using the present pump. The lengths of the hoses initially coming with the pump 

are different. For most applications, the shorter hose should be used as a suction hose, whereas the longer hose 

should serve as a pressure line. 

If you are using hoses other than those initially coming with the pump, please do make sure that they are suitable 

for pumping the specific liquid to be discharged. Also, the intake or pressure line should have the same diameter 

as the suction port (1) or pressure port (2) of the pump. 

.5. 

How to position the pump 

 

Please make sure that the pump is standing in a safe and solid position. The device must always be placed 

upright on an even surface. When selecting the installation site, please make sure that possible spilling of the 

liquid being pumped cannot cause any damage.  

The fuel nozzle should always be above the upper level of the pumping fluid. Otherwise, the so-called “siphoning 

effect“ may cause liquid to be discharged despite the fact that the pump is out of operation. 

Содержание 002650

Страница 1: ...08 Mode d emploi POMPE DE 75 16 57 3285 62 01 TR 50 ref 002650 Gebrauchsanweisung ELEKTROPUMPE ZUM F RDERN VON DIESEL KRAFTSTOFF HEIZ L UND RAPS L ELECTRIC PUMP FOR THE SUPPLY OF DIESEL FUEL HEATING O...

Страница 2: ...otto indicate sono costruiti in conformit con le direttive EU in vigore e loro successive modifiche Declaraci n CE de conformidad La empresa DIPRA declara bajo su propia responsabilidad que los produc...

Страница 3: ...75...

Страница 4: ...s 5 Druckanschluss 9 Entl ftungs ffnung 2 Ansaugleitung 6 Zapfpistole 10 Verschluss Entl ftungs ffnung 3 R ckschlagventil 7 Pumpengeh use 11 Druckleitung 4 Ansaugfilter 8 Schlauchschelle HA Ansaugh he...

Страница 5: ...aut surveiller les enfant pour tre s r qu ils ne jouent pas avec la pompe Les r glementations en vigueur dans diff rents pays limitent peut tre l ge de l usager Il est obligatoire de respecter incondi...

Страница 6: ...est livr avec les l ments suivants Une pompe avec c ble de raccordement XQ WX DX G DVSLUDWLRQ DYHF FODSHW FUpSLQH XQ WX DX G pYDFXDWLRQ DYHFY XQ SLVWROHW un mode d emploi Conservez si possible l emba...

Страница 7: ...nue et la pompe L avantage en cas de d montage de la pompe il suffit de fermer la soupape d arr t pour viter de vider la conduite de refoulement 5 Installation fixe Dans les installations fixes le bra...

Страница 8: ...un disjoncteur diff rentiel haute sensibilit 30 mA DIN VDE 0100 739 Les c bles de rallonge ne doivent pas avoir une section inf rieure celle du c blage en caoutchouc avec l abr viation H07RN F 3 x 1 0...

Страница 9: ...z la pompe du r seau lectrique Si la pompe n est pas d branch e vous courez le risque d un d marrage involontaire de la pompe La garantie du fabricant ne couvre aucun d g t occasionn par des manipulat...

Страница 10: ...ssent pas les valeurs maximales 4 La pompe n atteint pas la pression d sir e 1 Voir point 2 2 2 La turbine est us e 1 Voir point 2 2 2 Contactez votre revendeur 9 Garantie Cet appareil a t construit e...

Страница 11: ...e la garantie Seulement pour les pays de l U E Ne jetez pas les appareils lectriques lectroniques la poubelle Conform ment la directive europ enne 2012 19 EU sur les anciens quipements lectriques et l...

Страница 12: ...g instructions must not use this device Please keep an eye on children to make sure they will not use the unit as a toy to play with In various countries applicable provisions may be in place which mi...

Страница 13: ...rate Qmax 1 2 100 l h Max pressure 3 5 bar Max delivery height Hmax 1 35 m Max suction height 5 m Max size of the solids being pumped 0 mm Max ambient temperature 40 C Max fluid temperature Tmax 40 C...

Страница 14: ...Slide the fuel nozzle 6 onto the pressure line then fasten it in place using one of the hose clamps Continue by inserting one connection piece fully into the other end of the pressure line and fasten...

Страница 15: ...erable damage to the device In addition overheating bears the risk of injury by burning If the pump has run hot please unplug the mains plug and allow the system to cool down Please do not expose the...

Страница 16: ...ist below shows some possible malfunctions of the device possible causes and tips on their elimination All the measures referred to may only be carried out with the pump being separated from the elect...

Страница 17: ...s purchased 13 MALFUNCTION POSSIBLE CAUSE ELIMINATION 2 The motor is running but the pump is not discharging any liquid 1 The pump housing is not filled with liquid 2 Air penetrates into the intake li...

Страница 18: ...ssing upon the return of the device we shall not be liable for them 1 How to order spare parts For a list of available parts please contact your dealer DIPRA is working to supply main spare parts of t...

Страница 19: ...n d rfen dieses Ger t nicht benut zen Kinder sollten beaufsichtigt werden um sicherzustellen dass sie nicht mit dem Ger t spielen In verschiede nen L ndern g ltige Vorschriften begrenzen m glicherweis...

Страница 20: ...gepumpten Fl ssigkeit Tmax 40 C Anschlusskabel 1 5 m Kabelausf hrung H07RN F Gewicht netto 10 0 kg Garantierter Schallleistungspegel LWA 2 68 dB Gemessener Schallleistungspegel LWA 2 64 1 dB Schalldru...

Страница 21: ...fl ssigkeit zur Pumpe Schrauben Sie eines der Anschlussst cke zu sammen mit einem der Dichtungsringe an das R ckschlagventil 3 mit Ansaugfilter 4 Stecken Sie das andere Ende des Anschlussst cks bis zu...

Страница 22: ...Netzspannung entsprechen Die f r die Installation verantwortliche Person muss sicherstellen dass der elekt rische Anschluss ber eine den Normen entsprechende Erdung verf gt Der elektrische Anschluss...

Страница 23: ...st rungen und tr gt dazu bei die Lebensdauer Ihres Ger tes zu verl ngern Schmirgelnde Stoffe in der F rderfl ssigkeit wie beispielsweise Sand beschleunigen den Verschlei und reduzieren das Leis tungsv...

Страница 24: ...Ansaugleitung verstopft 5 Druckleitung verstopft 1 Das Pumpengeh use mit Fl ssigkeit be f llen siehe Abschnitt Installation 2 berpr fen und sicherstellen dass a die Ansaugleitung und alle Verbindun ge...

Страница 25: ...hr defektes Ger t zur Reparatur bringen oder einsenden entfernen Sie bitte alle hinzugef gten An bauteile die nicht dem Originalzustand des Ger tes entsprechen Sollten bei der R ckgabe des Ger tes sol...

Страница 26: ...SPIDO une marque de DIPRA 65 rue de Luzais 38070 SAINT QUENTIN FALLAVIER www dipra fr www spido bienchoisirmapompe fr...