SPD-2000 NS - Installation Instructions
INSTALLATION
General Information
Fig. 3 (shown directly below) details how to prepare the
SPD-2000 NS detector prior to mounting.
1
Remove cover
2
Install/replace battery
(proper polarity)
4
ON
OFF
2 3
1
Perform Function Sw. Setting
(See tables 1 & 2)
3
4
Mount bracket (option) on the mounting
surface, with double-sided adhesive tap or
with 2 screws, and insert the assembeld
detector into the bracket.
5
Press Tamper sw. once (for smooth
power-up) - verify that tamper message
is transmitted and LED is lit.
Close cover
6
Figure 3 :Detector Preparation Process
Battery
Battery
holder
clamps
Tamper
switch
SIP
Sw.
Sensor
card
LED
Figure 4: PCB Layout.
Table 1: Functions – Switches 1 & 2 (Mode Selection)
Page 2 of 3
Sw Pos
Description
OFF
*Alarm restore Disabled:
After the unauthorized
movement of the protected asset has ceased; no alarm
restore messages are transmitted and the detector
'Learns' the new location of the asset. Should the detector
sense subsequent asset movement a new alarm
message is transmitted.
1
ON
Alarm restore Enabled:
After any unauthorized
movement of the protected asset has ceased an alarm
restore message is transmitted.
OFF
Location Monitoring Disabled:
When the protected
asset commences unauthorized motion, a single alarm
message is transmitted. Supervisory messages transmit
hourly.
2
ON
Location Monitoring Enabled:
When the protected
asset commences unauthorized motion. Location
monitoring messages transmit in 30 second intervals for
up to 10 minutes after movement has ceased.
Supervisory messages transmit in 15 minute intervals.
* The detector requires approximately 10 minutes to 'Learn' the location of
the protected asset.
Table 2: Sensitivity Selection Functions - Switch 3 & 4 ()
Switch 3 Switch 4
Sensitivity Level
OFF OFF
1. “Strong movement" (lowest sensitivity)
ON OFF
2. “Move”
OFF ON
3. “Slide”
ON ON
4. “Touch” (highest sensitivity)
Mounting Details
Attach the SPD-2000 NS to a corner of the asset you wish to
protect using double-side adhesive tape or by means of an
optional mounting bracket. If required, you the detector can be
affixed to either the far left or far right side of the asset as
well.
Caution:
Verify that the “UP” arrow is pointing upwards
(allowed deviation: up to
±
25
°
in the vertical and horizontal
axes).
Field Testing
Wait 10 minutes after attaching the detector to an asset so
that the detector may 'Learn' the location of the asset. Then
move the asset to verify that alarm messages are being
transmitted by the detector and that the function LED
illuminates.
Miscellaneous Operating Information
Due to the low transmitting power and the limited range of this
RFID device (as required by the FCC and other international
regulating authorities), there are a number of operational
limitations that need to be considered considered and
handled:
•
Receivers may be blocked by radio signals that occur on
or near their operating frequencies.
•
A receiver can only respond to one transmitted signal at a
time.
•
Wireless equipment should be regularly tested to
determine current sources of interference and to protect
against faults.
Battery Safety and Disposal
Promptly remove the worn-out battery from the detector and
dispose of according to manufactuer's instructions. For more
information, contact your local government for the disposal or
recycling practices in your area.
CAUTION:
To eliminate the risk of possible explosion, do not
attempt to replace the battery with a non-specified type.
DE3650