SpiderAlert SPD-2000 NS Скачать руководство пользователя страница 2

SPD-2000 NS - Installation Instructions 

 

 

 
 

INSTALLATION 

 

General Information 

Fig. 3 (shown directly below) details how to prepare the  
SPD-2000 NS detector prior to mounting. 

 
 

 
 

1

Remove cover

2

Install/replace battery

(proper polarity)

4

ON

OFF

2 3

1

Perform Function Sw. Setting

(See tables 1 & 2)

3

4

Mount bracket (option) on the mounting

surface, with double-sided adhesive tap or

with 2 screws, and insert the assembeld

detector into the bracket.

5

Press Tamper sw. once (for smooth

power-up) - verify that tamper message

is transmitted and LED is lit.

Close cover

6

 

 

Figure 3 :Detector Preparation Process 

 

Battery

Battery

holder

clamps

Tamper

switch

SIP

Sw.

Sensor

card

LED

  

 

Figure 4: PCB Layout.

 

 

Table 1: Functions – Switches 1 & 2 (Mode Selection) 

 

Page 2 of 3

 

 

Sw  Pos 

Description 

OFF

 

*Alarm restore Disabled:

 After the unauthorized 

movement of the protected asset has ceased; no alarm 

restore messages are transmitted and the detector 

'Learns' the new location of the asset. Should the detector 

sense subsequent asset movement a new alarm 

message is transmitted.

 

ON

 

Alarm restore Enabled:

 After any unauthorized 

movement of the protected asset has ceased an alarm 

restore message is transmitted.

 

OFF

 

Location Monitoring Disabled: 

When the protected 

asset commences unauthorized motion, a single alarm 

message is transmitted. Supervisory messages transmit 

hourly.

 

2

 

ON

 

Location Monitoring Enabled: 

When the protected 

asset commences unauthorized motion. Location 

monitoring messages transmit in 30 second intervals for 

up to 10 minutes after movement has ceased. 

Supervisory messages transmit in 15 minute intervals.

 

 

* The detector requires approximately 10 minutes to 'Learn' the location of 

the protected asset.  

 

Table 2: Sensitivity Selection Functions  - Switch 3 & 4 () 

 

Switch 3  Switch 4 

Sensitivity Level 

OFF OFF 

1. “Strong movement" (lowest sensitivity) 

ON OFF 

2. “Move” 

OFF ON 

3. “Slide” 

ON ON 

4. “Touch” (highest sensitivity) 

 

Mounting Details 

 

Attach the SPD-2000 NS to a corner of the asset you wish to 

protect using double-side adhesive tape or by means of an 

optional mounting bracket. If required, you the detector can be 

affixed to either the far left or far right side of the asset as 

well. 

 

Caution: 

Verify that the “UP” arrow is pointing upwards 

(allowed deviation: up to 

±

 25

°

 in the vertical and horizontal 

axes).

 

 

Field Testing 

 

Wait 10 minutes after attaching the detector to an asset so 

that the detector may 'Learn' the location of the asset. Then 

move the asset to verify that alarm messages are being 

transmitted by the detector and that the function LED 

illuminates. 

 

Miscellaneous Operating Information 

 

Due to the low transmitting power and the limited range of this 
RFID device (as required by the FCC and other international 
regulating authorities), there are a number of operational 
limitations that need to be considered considered and 
handled: 

  Receivers may be blocked by radio signals that occur on 

or near their operating frequencies. 

  A receiver can only respond to one transmitted signal at a 

time. 

  Wireless equipment should be regularly tested to 

determine current sources of interference and to protect 
against faults. 

 

Battery Safety and Disposal 

 

Promptly remove the worn-out battery from the detector and 
dispose of according to manufactuer's instructions. For more 
information, contact your local government for the disposal or 
recycling practices in your area. 

 

CAUTION:

 To eliminate the risk of possible explosion, do not 

attempt to replace the battery with a non-specified type. 
 
 
 

 