Thermo 230 / 231 / 300 / 301 / 350
5 Troubleshooting
507
5.3.2.7 Fault Symptom "Solenoid Valve Defective"
Is solenoid valve supplied
with electrical power ?
YES
NO
Is components test with diagnostic computer o.k.
(audible click of solenoid valve)?
Make electrical connections.
Control unit defective, replace.
Does fuel leak from nozzle in run-down?
Replace solenoid valve.
Investigate reason for response
(e.g. check exhaust system)
Has safety thermostat responded ?
(Thermo 231/301 only)
Safety thermostat defective,
replace.
Replace solenoid valve.
Содержание thermo 231
Страница 2: ......
Страница 10: ...1 Introduction Thermo 230 231 300 301 350 104 Page empty for notes...
Страница 26: ...4 Technical Data Thermo 230 231 300 301 350 404...
Страница 50: ...7 Circuit Diagrams Thermo 230 231 300 301 350 712...
Страница 72: ...10 Packaging Storage Shipping Thermo 230 231 300 301 350 1002 Page empty for notes...
Страница 73: ...Thermo 230 231 300 301 350 Annex A A 1 Annex A Scheduled Maintenance...