3.4 Load Mode Setting Interface
3.4.1 Load modes introduction
This controller has 5 load operating modes which will be described below:
No.
Mode
Descriptions
0
Sole
light
control
(nighttime
on
and
daytime off)
When no sunlight is present, the solar panel voltage is lower than the light control on
voltage, and after a time delay, the controller will switch on the load; when sunlight
emerges, the solar panel voltage will become higher than the light control off voltage,
and after a time delay, the controller will switch off the load.
1 to 14
Light control + time
control 1 to 14 hours
When no sunlight is present, the solar panel voltage is lower than the light control on
voltage, and after a time delay, the controller will switch on the load. The load will be
switched off after working for a preset period of time.
15
Manual mode (Default)
In this mode, the user can switch the load on or off by the keys, no matter whether it's
day or night. This mode is designed for some specially purposed loads, and also used
in the debugging process.
16
Debugging mode
Used for system debugging. With light signals, the load is shut off; without light
Main monitoring page
Component voltage
Charging current
Abnormality code
Battery voltage
Battery capacity
Load current
Charging capacity
Load mode
Discharging capacity
Device temperature
More information https://www.caravansplus.com.au