5-3. DC Voltage

1. Install the test leads 

2. Rotate the dial to the          position

3. Confirm DC V is displayed on the LCD screen

4. If DC V is not displayed press the SEL key to toggle between ACV and DCV

5. Connect the test leads to the circuit

6. The DC voltage will be displayed on the LCD screen

5-4. AC Voltage

1. Install the test leads 

2. Rotate the dial to the          position

3. Confirm AC V is displayed on the LCD screen 

4. If AC V is not displayed press the SEL key to toggle between DCV and ACV

5. Connect the test leads to the circuit

6. The AC voltage will be displayed on the LCD screen 

5-5. AC Current

1. Remove the test leads

2. Rotate the dial to the 60àor 600àposition

3. Press the trigger to open the clamp jaws and place the jaws around a single conductor.

4. The current flowing through the conductor will be displayed on the LCD screen 

5-6. Frequency

1. Set up the meter for an AC voltage or current measurement and press the Hz% button

2. "Hz" should be displayed on the LCD screen

3. Connect the test leads probes to the circuit

2. The meter will display the measured frequency on the LCD screen

5-7. Duty cycle

1. Set up the meter for an AC voltage or current measurement and press the Hz% button

2. "Hz" should be displayed on the LCD screen

3. Press the Hz% button a second time and "%" should be displayed

4. The meter will display the measured duty cycle on the LCD screen

5-8. Inrush

1. Remove the test leads

2. Rotate the dial to the 60àor 600àposition

3. Press the INR/REL button for 2 seconds or more

4. Confirm "INRUSH" is displayed on the LCD screen

5. Turn off the device of which you will be checking the inrush current

5-2. Resistance / Continuity / Diode / Capacitance

Resistance

1. Install the test leads 

2. Rotate the dial to the        position

3. Confirm “OL” is displayed on the LCD screen

4.  Short the tips of the test leads together and  

confirm the LCD screen shows near zero

5.  Connect the test leads across the device  

to be tested

6.  The resistance of the device will be displayed  

on the LCD screen

Continuity

1. Install the test leads 

2. Rotate the dial to the        position

3.  Press the SEL button to toggle through the functions  

until        is displayed on the LCD screen

4. Confirm “OL” is displayed on the LCD screen 

5.  Short the tips of the test leads together and the LCD screen 

should show near zero and the meter should emit a tone

6. Connect the test leads across the device to be tested

7. A tone will be emitted if the resistance is < 50

Ω

Diode test

1. Install the test leads 

2. Rotate the dial to the        position

3.  Press the SEL button to toggle through the functions  

until        is displayed on the LCD screen

4. Confirm “OL” is displayed on the LCD screen 

5.  Connect the test leads probes to the anode and  

cathode of the diode

6. Record the measurement displayed

7.  Reverse the connections and record the  

measurement displayed

(The LCD screen should show ”OL” in one direction and a small 

forward voltage drop in the other. The forward voltage drop 

varies. Typical values are .7V for silicon diodes and .3V for 

geranium diodes. Please refer to the diode datasheet for specific 

values. If there is a voltage drop in both directions the diode is 

shorted. If “OL” is displayed in both directions the diode is open)

Capacitance

1. Remove the capacitor from the circuit

2. Ensure that the capacitor is properly discharged

3. Install the test leads 

4. Rotate the dial to the        position

5.  Press the SEL button to toggle through the functions  

until "nF" is displayed on the LCD screen

6.  Connect the test leads to the capacitor terminals. (It will take  

a few seconds for the capacitance to be displayed)

Содержание DSA600TRMS

Страница 1: ...erminal Input Terminal Peak Button PEAK HOLD HOLD Backlight Clamp Light Dial Frequency Duty Cycle Hz Inrush Current Relative Measurement INR REL 1 Figure 2 Data Hold AC Alternating Current Low Battery...

Страница 2: ...tion manual contains warnings and safety rules which must be observed by the user to ensure safe operation of the instrument and retain it in safe condition Read through and understand the instruction...

Страница 3: ...horoughly before use Measurement categories Over voltage categories To ensure safe operation of measuring instruments IEC61010 establishes safety standards for various electrical environments specifie...

Страница 4: ...0A 0 01A 5 60 600A 1A Input impedance 10M Maximum input voltage 600V AC RMS Frequency range 40 1000Hz AC VOLTAGE RANGE RESOLUTION ACCURACY 6V 0 001V 1 2 5 60V 0 01V 0 8 5 600V 0 1V Duty ratio Clamp Ja...

Страница 5: ...ity Do not use test leads in applications that exceed their CAT rating Check the CAT rating of the test lead and refer to Figure 3 4 5 Checking the switch setting operation Confirm the dial is set to...

Страница 6: ...nstall the test leads 2 Rotate the dial to the position 3 Confirm OL is displayed on the LCD screen 4 Short the tips of the test leads together and confirm the LCD screen shows near zero 5 Connect the...

Страница 7: ...measuring range OL or OL is displayed on the LCD screen 6 Press the trigger to open the clamp jaws and place the jaws around a single conductor Easily accomplished with the use of a line splitter 7 T...

Страница 8: ...the Function Switch to OFF and remove the test leads from the instrument before trying to replace batteries 7 BATTERY REPLACEMENT WARNING Test on a known live source before use Even if the meter does...

Страница 9: ...ts shall not have been altered by the distributor The distributor shall be fully responsible for any warranties the distributor makes to its purchasers which are broader or more extensive than Sperry...

Отзывы: