Adapter calibration
In order to check and re-calibrate the zero, select the adapter you want to calibrate from the adapter list and then
“Start adapter zeroing procedure”
Press F2
The adapter calibration window will be displayed.
Here you can simply follow the steps in the diagram:
1. Move the referral notch in the FOV. Try to center it as much as possible.
On the external part of the tool holding cone, on the machine’s spindle, there is a referral notch (R), which simulates the cutting
edge of a tool. On the wheel of the spindle there is always a plate (T) where you can read the referral values which define the
0 (zero).
2. Find the maximum diameter using the “Focus bar”.
3. Check if the referral notch is perfectly cleaned using the “Tool cleaning kit”
4. Store the zero point measurement with
“Start adapter zeroing procedure”
F2
A message will let you know if the procedure is carried out correctly.
Press F10 to exit.