5. Safety instructions
5.1. Storage and transport
The rescue equipment should be stored in dry and cool rooms and protected against
UV irradiation. Avoid contact with acids, corrosive liquids and oils. In case the
unavoidable moisture penetration of the rope, these should be dried naturally and not
using heat sources.
A stable device bag or device case should always be used to transport the rescue
equipment in order to avoid damage due to external effects.
5.2. Servicing and cleaning
A visual inspection of the rescue equipment must be conducted before every use in
order to ensure that the device is operational.
If damage to the rope, karabiner or descender device is detected, the use of the
rescue equipment must be stopped and the device must be checked by the
manufacturer or a body authorised by him/her.
Note:
No changes or additions must be made to the descender and rescue lifting
device; else, the type e xamination is no longer valid.
Use a dry cloth or brush to clean the housing. The rope can be cleaned with
lukewarm water and mild soap followed by rinsing with plain water. Ensure that it is
completely dry before packaging. Do not use heat sources!
5.3. Period of wear
The period of wear depends on the relevant operating conditions. Based on the
present experiences, a period of wear for textile ropes could be 4 to 7 years under
normal operating conditions. The device can be used for many more years
depending on the storage and operating conditions.
5.4. Regular inspections
The rescue equipment must be tested at least once a year by the manufacturer or an
expert, e ven if it is not in use. If damage is detected during this inspection or there
are doubts regarding the usability of the equipment, the device must be sent to the
manufacturer or a service centre authorised by him.
This expert testing must be conducted at least every 7 years either by the
manufacturer himself/herself or by an expert authorised by him/her.