Monthly Inspection 

•  

Never

 pull, drag, or lift the Fendall 2000™ Heated Accessory by the 

    power cord.
•  

Never

 use ungrounded, worn or damaged extension cords.

•  

Never

 connect to a higher voltage power supply than what is 

    listed on the cord.  

(Fig. 5)

•  

Never

 connect the heated accessory to a power source when rolled or folded.

•  

Do not submerge

 the heated accessory in water. They are water resistant, 

    not waterproof. Keep them out of flooded areas and make sure to use 
    grounded extension cords with a working GFCI circuit.
•  Clean surfaces daily of all dirt and debris with a mild soap and warm water; 
    then inspect for rips, tears or holes of any kind.
•  

Do not return to service until repaired or patched.

  Patch all holes using the Fendall 2000™ Heated Accessory Vinyl Repair Kit 

    (32-002002-0000).  Caution, not using Fendall 2000™ Heated Accessory Vinyl Repair Kit may void your warranty, contact your 
    local distributor or Sperian directly for ordering or more information.
•  Prepare for storage by removing all debris that can pierce the outer shell. If possible avoid folding the heated accessory as this 
    will increase the heated accessory longevity.      

 

Volts

Fig. 5

OHMS

2

Handling and Maintenance  

This is to perform the required Monthly Maintenance Check on the Fendall 2000™ with Heated Accessory.

1)  Unplug the Heated Accessory.
2)  Open the front access panel in the center of the front door. 

(Fig. 4)

3)  Use screw driver or pen to push on release button.
4)  While button is pressed in, gently pull door open (there should be no resistance, other than the Velcro™).
5)  Push the blue button and hold for 3 seconds until a beep is heard to disarm the alarm.  

NOTE:

 Short beep once every 10

     seconds indicates a low battery.
6)  Inspect the nozzle for correct attachment, and hose for possible kinking. Re-position if needed.  

NOTE:

 Be sure the nozzle seal

     is intact.
7)  Unzip the Heated Accessory to check the Cartridge Expiration date through the window on the eyewash station.  Check the
     bellows to make sure that it is not in the deployed position and that the cartridge has not been activated.  Replace the
     cartridge if expired or activated.
8)  Zip up the Heated Accessory and follow steps 9 - 11 on page 1.

Fig. 4

Front Door

Front Access Panel

Troubleshooting  

• Please contact Sperian for more assistance (1-800-336-3255).                

CAUTION

If power is lost for any amount of time, the GFCI 

will need to be manually reset for the Heated 

Accessory to function.