Страница 2: ...2 TABLE OF CONTENTS Introduction 3 Front Panel Description 4 Measurement Procedures 7 Set Up Calibration 11 Nice Flow App 15 Error Codes 19 Specifications 21 Warranty 24...

Страница 3: ...ndroid apps and export a summary the data together for later analysis The app will also superimpose current readings of all parameters on your smart phone photo of the object being measured Simple use...

Страница 4: ...eezes the current reading MAX MIN Maximum and minimum reading AVG Multi points timed average Battery Low voltage indicator ppm CO2 unit m s fpm Air velocity unit RH Relative humidity unit o C o F Temp...

Страница 5: ...um and Maximum values Hold down again to return to normal mode In average mode press to record data or start timed recording In setup mode press to enter data settings With the meter on press Lmode to...

Страница 6: ...display of air velocity RH Relative Humidity or CO2 In average mode press to view recorded and average reading of all parameters In setup mode press to select category or decrease value Press simultan...

Страница 7: ...ff has been disabled Display Units When initially powered on the meter displays air velocity in the upper display and air temperature in the lower display Press Umode to cycle upper display readings o...

Страница 8: ...turned on will be displayed 3 Press the up arrow to scroll minimum and maximum parameters in the upper display and press the down arrow to scroll parameters in the lower displays 4 Press Mx Mn again f...

Страница 9: ...mal mode Timed Average 1 In normal mode press AVG for 2 seconds and the meter enters multi point average mode Press it again to enter Timed Average mode 2 Press enter to start recording The upper disp...

Страница 10: ...the meter is fully inserted and locked into the cone indicates that it recognizes the cone The meter will now automatically calculate air volume without reference to any measurements you may have prev...

Страница 11: ...following options P1 0 Unit selection P2 0 Area input P3 0 RH offset P4 0 Pressure compensation P1 0 Unit Selection 1 Press enter to enter unit selection mode 2 Press arrow to switch from metric to im...

Страница 12: ...set RH value can be adjusted to any known standard 1 Press enter to enter the RH Offset mode 0 0RH flashes on the upper display 2 Press to increase and to decrease the offset value i e the difference...

Страница 13: ...is calibrated at 400ppm CO2 concentration at the factory We suggest recalibrating at least once a year for the best accuracy This should be done in fresh air equals 400ppm Calibrating the meter in hig...

Страница 14: ...420 will flash in the upper display 3 After 10 minutes the reading will stop flashing calibration is complete and the meter returns to normal Note Make sure the batteries are at full voltage during t...

Страница 15: ...up to 5 meters can viewed simultaneously a Device Name b Display Preferences All measurement parameters are initially displayed You may remove any parameter from the App display simply by clicking on...

Страница 16: ...essure at your current location b Camera Allows the App to superimpose measurement data on photos taken with your smartphone These will be saved to your phone s camera file for later viewing or inclu...

Страница 17: ...17 d Average Press to enter timed average mode Press to enter multi point average mode Press to record Press to stop recording Files are saved automatically...

Страница 18: ...a serial number sequence number and date The latter two can be replaced with a file name of your choosing To change the name Check the box to the right of the file then tap rename at the bottom of the...

Страница 19: ...re the temperature reading E031 Temperature circuit damaged Return to Sper Scientific for repair RH E04 RH error caused by temperature error See Temperature errors and solutions above E11 RH calibrati...

Страница 20: ...r still persists return to Sper Scientific for repair E01 E33 Volatge too low or CO2 module error Check the low battery icon and replace if necessary Recalibrate and if the error persists return to Sp...

Страница 21: ...o C to 60o C 0 1o F 0 01o C 0 9o F 0 6o C Relative Humidity 0 to 99 9 0 1 3 at 10 to 90 RH otherwise 5 Dew Point 8 to 140o F 5 to 59 9o C 0 1o Wet Bulb Temperature 100 to 140o F 20 to 59 9o C 0 1o Air...

Страница 22: ...mply with part 15 of the FCC Rules Operation is subject to the two following conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received includi...

Страница 23: ...23 OPTIONAL ACCESSORIES 900031 Airflow Cone Kit 900032 Extension Rod...

Страница 24: ...rranty does not cover batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the thermometer to expose its electronics will void the warranty To o...

Отзывы: