background image

Once the measurement time is set, there will be a short beep sound 

as remind at the end of the measurement. It displays dose accumu

-

lative value at that time, and the TIME icon shows and stops flash

-

ing. If it is not coming to the timing time yet, press “SV” button into 

non-timing accumulation state or recording state. if long press this 

button, you will re-enter into the timing setup mode .

Two methods for stopping the measurement:

Under non-timing condition, short press “SV” button for the 2nd time, 

stops the accumulate measurement, and into timing measurement; 

during the process of the timing measurement, short-pressing this 

button will stop accumulative measurement state.
Choosing other operation mode to zero the measurement results.

6-6. Pulse counting

The multi-function digital nuclear radiation scanner can be also used 

as an ordinary Geiger counter. Under the setting, it only records re

-

ceived pulse and calculate pulse, it will not be switched to Sv ( Dose 

equivalent unit, 1Sv = 100Rem ) . The meter shows the received 

accumulative value of the pulse on LCD.

6-7. Pulse counting measuring button

 

1. Pulse Rate Value Indication ( CPS/CPM )
In radiation ray pulse rate testing mode, radiation ray pulse is con

-

stantly measured by counter tube and then transfer into pulse rate.
Press “CPS/CPM” button once and then press the button again into 

pulse rate unit switch between CPS and CPM.

CPS : 

pulse number per second

CPM : 

pulse number per minute

2. Press “CPS/CPM”key for the 3rd time into pulse counting mode, 

and it will display the pulse icon. Press the”CPS/CPM” button again 

(the 4th time) to end pulse counting. There will be a beep sound as a 

remind of entering into timing pulse counting mode, and shows

10

the pulse and timing flashing icon on display; press this button again 

to stop pulse counting; pressing once again will return to CPS pulse 

counting function.
3. Long press “CPS/CPM” button for two seconds or under “pulse” 

measurement mode, and will enter into measuring time setup mode, 

and the screen shows “pulse” and “time” icon. At this time, the dis

-

play shows three digits, default value is 060, means 60 minutes, max 

to 999 minutes, and the first digit(the hundreds) is in blinking state, 

and this value can be set directly.
press      enter key for the first time to set tens digit 
press      enter key for the second time to set single digit;
press      ESC button and return to the previous state;
press      enter button the third time to confirm and complete time 

input and show the current setting value;
press      enter button for the fourth time, enter into timing dose 

accumulative working state, and the icon “time” on the top left corner 

starts flashing;
press       down key or       up key to adjust the display value.
If measurement time is set, there will be a short beep sound at end 

of the measurement.
By then, it will display the measured accumulative value at that time.
Meanwhile, the TIME icon will be shown and stops flashing.
Two methods for stopping the measurement:
Under not-timing condition, short press “CPS/CPM” pulse button for 

the 4th time, end of the accumulative measurement, and into timing 

measurement; during the timing measurement, short press this but

-

ton to stop the accumulative measuring state.
Choosing other operation mode, then measuring results disappear.

6-8. Menu setup

Press “setup” button into menu setting interface: Date, time, alarm, 

pulse volumn     , average time set(T), Bluetooth wireless data trans

-

mission(BT); 1 minute after press the button and left it untouched, it 

will automatically return to “µSv/h” measurement mode.

11

Содержание 840023

Страница 1: ...MULTI FUNCTION DIGITAL RADIATION DETECTOR 840023 ...

Страница 2: ...ion data transmission and powerful software for data evaluation It can detect a β y and X ray It also can detect radiation pulse times This meter can be widely used in pharmaceutical factory s laboratory s power stations stone pits emergency rescue stations metal plants oil fields and the oil pipelines environmental protections police depart ments and etc This meter can detect Groundwater radium p...

Страница 3: ... confirm button 9 ESC exit button in any setting or mea suring conditions press this button can return to Setup state 10 Power consumption measurement of batter and parameter setting up key 11 SV unit accumulating count key and timing measuring key 12 CPS CPM pulse counting measurement unit switch button 4 4 LCD display symbol description 1 Boot nuclear radiation ray measuring dynamic icon indicat...

Страница 4: ...European CE US FCC 15 Warranty One year for the main engine 6 7 Note Sievert mark is Sv unit 1Sv 100 rem rem roentgen equivalent man µSv h unit of ray radiation dose rate 1SV 100Rem 1 rem 1cSv 10mSv 1uR h 10uSv h 1 mR h 10mSv h CPS pulse times per second In the pulse rate model pulse has constantly been measured by counter tube and translated into pulse rate CPM pulse counts per minute ln the puls...

Страница 5: ...on The digital nuclear radiation scanner could also do the measure ment recording the accumulated radiation dose at specific time The initial unit is µSv and it will automatically convert to mSv or Sv as the measured dose rate getting higher 6 5 Button for Dose Rate accumulation 1 Press SV button and enter into the regular infinite dose rate accumulation calculation mode with dose rate icon µSv on...

Страница 6: ...into timing pulse counting mode and shows 10 the pulse and timing flashing icon on display press this button again to stop pulse counting pressing once again will return to CPS pulse counting function 3 Long press CPS CPM button for two seconds or under pulse measurement mode and will enter into measuring time setup mode and the screen shows pulse and time icon At this time the dis play shows thre...

Страница 7: ... method of DATE setup as above hour minute second 12 6 11 Alarm Threshold Value Setup default value is 205uSv h 1 Press SETUP button once then select ALM BL icon through UP or DOWN button Then the ALM icon will flash press EN TER button to confirm your option and press ENTER button once again to set the single digit ten digit and hundred digit The related digit will flash and can be adjusted by pr...

Страница 8: ...cally record the measure ment data during the transmission For the connection with PC pis refer to the software operation instruction 7 Battery Voltage Detection function 1 The multi function digital nuclear radiation scanner uses sup per powerful Lithium battery Press UP or BATTERY DETECTION button it will display the inter nal battery voltage normal voltage is 2 7V to 3 7V 2 Press ESC button to ...

Страница 9: ...ble This warranty does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will void the warranty To obtain warranty service ship the unit postage prepaid to SPER SCIENTIFIC LTD 8281 E Evans Rd Suite 103 Scottsdale AZ 85260 The defective unit must be accompanied by a description of the pro...

Отзывы: