Once the measurement time is set, there will be a short beep sound
as remind at the end of the measurement. It displays dose accumu
-
lative value at that time, and the TIME icon shows and stops flash
-
ing. If it is not coming to the timing time yet, press “SV” button into
non-timing accumulation state or recording state. if long press this
button, you will re-enter into the timing setup mode .
Two methods for stopping the measurement:
Under non-timing condition, short press “SV” button for the 2nd time,
stops the accumulate measurement, and into timing measurement;
during the process of the timing measurement, short-pressing this
button will stop accumulative measurement state.
Choosing other operation mode to zero the measurement results.
6-6. Pulse counting
The multi-function digital nuclear radiation scanner can be also used
as an ordinary Geiger counter. Under the setting, it only records re
-
ceived pulse and calculate pulse, it will not be switched to Sv ( Dose
equivalent unit, 1Sv = 100Rem ) . The meter shows the received
accumulative value of the pulse on LCD.
6-7. Pulse counting measuring button
1. Pulse Rate Value Indication ( CPS/CPM )
In radiation ray pulse rate testing mode, radiation ray pulse is con
-
stantly measured by counter tube and then transfer into pulse rate.
Press “CPS/CPM” button once and then press the button again into
pulse rate unit switch between CPS and CPM.
CPS :
pulse number per second
CPM :
pulse number per minute
2. Press “CPS/CPM”key for the 3rd time into pulse counting mode,
and it will display the pulse icon. Press the”CPS/CPM” button again
(the 4th time) to end pulse counting. There will be a beep sound as a
remind of entering into timing pulse counting mode, and shows
10
the pulse and timing flashing icon on display; press this button again
to stop pulse counting; pressing once again will return to CPS pulse
counting function.
3. Long press “CPS/CPM” button for two seconds or under “pulse”
measurement mode, and will enter into measuring time setup mode,
and the screen shows “pulse” and “time” icon. At this time, the dis
-
play shows three digits, default value is 060, means 60 minutes, max
to 999 minutes, and the first digit(the hundreds) is in blinking state,
and this value can be set directly.
press enter key for the first time to set tens digit
press enter key for the second time to set single digit;
press ESC button and return to the previous state;
press enter button the third time to confirm and complete time
input and show the current setting value;
press enter button for the fourth time, enter into timing dose
accumulative working state, and the icon “time” on the top left corner
starts flashing;
press down key or up key to adjust the display value.
If measurement time is set, there will be a short beep sound at end
of the measurement.
By then, it will display the measured accumulative value at that time.
Meanwhile, the TIME icon will be shown and stops flashing.
Two methods for stopping the measurement:
Under not-timing condition, short press “CPS/CPM” pulse button for
the 4th time, end of the accumulative measurement, and into timing
measurement; during the timing measurement, short press this but
-
ton to stop the accumulative measuring state.
Choosing other operation mode, then measuring results disappear.
6-8. Menu setup
Press “setup” button into menu setting interface: Date, time, alarm,
pulse volumn , average time set(T), Bluetooth wireless data trans
-
mission(BT); 1 minute after press the button and left it untouched, it
will automatically return to “µSv/h” measurement mode.
11