Sper scientific 800201 Скачать руководство пользователя страница 14

14

TO DOWNLOAD IMAGES

1.  Flip open the door on the left-hand side of the camera to 

expose the micro USB port.

2.  Plug in the included micro USB Cable, ensuring the cable 

seats fully. 

3. Attach the USB end of the cord to a computer. 
4.  The computer will automatically recognize the camera as 

a storage device.

5. Click “open folder to view files.”
6.  You can now rename, save, delete, copy, and share all 

images within the camera.

CARE AND MAINTENANCE

•  Store the camera in its protective case with the lens cover 

closed to prevent debris from entering the lens area.

•  Use only the recommended battery when replacement 

 

is needed.

•  Periodically wipe the camera with a dry, lint-free 

antistatic cloth.

•  Do not use abrasives, solvents or cleaning agents 

containing carbon, alcohol or benzenes on the meter.

•  Repairs or services not covered in this manual should 

be performed by qualified personnel only. Please contact 

Sper Scientific to speak with a technician.

Содержание 800201

Страница 1: ...1 Thermal Imaging Camera 220 x 160 800201 Instruction Manual...

Страница 2: ...OF CONTENTS INTRODUCTION 3 FEATURES 4 MATERIALS SUPPLIED 4 FRONT PANEL DESCRIPTION 5 LCD DISPLAY 6 SET UP 7 MEASUREMENT PROCEDURES 12 IMAGE DOWNLOADING 14 CARE AND MAINTENANCE 18 SPECIFICATIONS 19 WAR...

Страница 3: ...utiful 3 5 full color display Five available thermal color palettes and an impressive 35 200 pixel resolution ensure the images are crystal clear and can easily be placed in reports and presentations...

Страница 4: ...er for protection User defined crosshair pinpointing Minimum and Maximum values Adjustable emissivity 0 5m focal length Rechargeable Lithium ion battery MATERIALS SUPPLIED Thermal Imaging Camera Carry...

Страница 5: ...5 FRONT PANEL DESCRIPTION 1 2 3 4 5 6 7 8 1 POWER Button 2 MENU Button 3 SELECT Button 4 ENTER Button 5 RIGHT Arrow Visual Image Toggle 6 DOWN Arrow 7 LEFT Arrow 8 UP Arrow MIN MAX Toggle...

Страница 6: ...shair 2 Minimum Temperature Location Green Square 3 Maximum Temperature Location Red Square 4 Current Maximum and Minimum Values 5 Battery Level Indicator 6 Emissivity Indicator 7 Color Palette Indica...

Страница 7: ...era 5 The charging icon will appear in the upper right corner of the screen TO REPLACE THE BATTERY Note Before replacing the battery turn the camera off 1 Ensure the replacement battery is a direct re...

Страница 8: ...conds to turn on This is normal 3 Press and hold POWER until Power off displays on the screen The camera will turn off after a five second count down SETTING THE DATE AND TIME 1 Turn the camera on 2 P...

Страница 9: ...normal Camera Mode Note The Date and Time must be entered in military format regardless of the time format setting you select For example 6pm must be entered as 18 00 00 Once in measuring mode AM PM w...

Страница 10: ...stom value 7 The camera will return to the previous settings page 8 Press MENU to return to normal Camera Mode CHOOSING THE COLOR PALETTE 1 Turn the camera on 2 Press MENU 3 Press the DOWN arrow to hi...

Страница 11: ...aging Camera will always provide temperature data for the entire image on the screen It cannot differentiate between the objects within the image Therefore you must pay attention to where the square m...

Страница 12: ...photograph The thermal readings are still functioning 5 Press the RIGHT arrow to begin blending the thermal image with the visual 6 Continue to press RIGHT up to 4 more times to continue blending the...

Страница 13: ...press MENU 2 Use the UP and DOWN arrows to select Images 3 Press the RIGHT arrow to expand Images 4 Use the UP and DOWN arrows to choose the image you want to view 5 Press SELECT to open the chosen i...

Страница 14: ...lete copy and share all images within the camera CARE AND MAINTENANCE Store the camera in its protective case with the lens cover closed to prevent debris from entering the lens area Use only the reco...

Страница 15: ...0 99 Available Color Palettes Spectral rainbow iron oxide cool color black and white white and black Capture Frequency 8Hz Focal Length 0 5 meters Temperature Range 20 C 300 C 4 F 572 F Internal Stora...

Страница 16: ...ble This warranty does not cover batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will void the warranty...

Отзывы: