2.3

 

Contraindications and side effects

 

The use of this device, if used as described in this manual, does not present any contraindications or 
collateral effects. 
 

2.4

 

Physical requirements of the operators

 

The series of Spencer Rock spine boards is a device destined to professional use only. The rescue 
operators must have the following minimum requirements: 

 

physical capacity for operating the device 

 

be able to seize the device firmly with both hands 

 

have strong back, arms and legs for lifting, pushing and pulling the device 

 

have a good muscular coordination 

Every operator must be trained in efficient and safe patient transport. 
 
Patient  loading  procedures  for  extremely  heavy  patients,  operations  in  rough  terrain  and  in 
particular situations more operators may be needed (not only as in normal conditions). 
 

The capacities of the operators must be considered before determining their roles in the 
employment of the device.  
 

3. DESCRIPTION OF PRODUCT 

3.1

 

Intended use

 

The  Rock  series  spine  boards  are  devices  for  the  immobilization  of  the  patient  with  suspected 
traumatic injury. Basic device for emergency trauma care, the Spencer Rock spine board is based on 
the concept of absolute versatility. Using the four skids of high density polyethylene, Spencer Rock 
can  slip  on  the  steps  of  the  stairs.  It  ensures  in  all  situations  a  proper,  safe  and  secure  total 
immobilization of the spine and of the patient. The material and the construction technique confer 
the Spencer Rock exclusive characteristics: rigidity, water resistance, buoyancy, resistance to impact 
and corrosion, X-ray homogeneity and compatibility. 
The model Rock Pin presents in the lateral handles rapid anchoring elements, X-ray compatibles, for 
fastening the dedicated immobilisation system. 
 

3.2

 

Main components 

The device consists of the following main components: 

 

polyethylene shell 

 

plugs (2 pcs) 
 

3.3

 

Models 

ST02030A

 

Spencer Rock – Spine board, orange

 

ST02014B

 

Rock Pin – Spine board with pins, military

 

ST02051A

 

Spencer Rock – Spine board, yellow

 

ST02110B  Rock Pin Max – Spine board with pins, yellow

 

ST02032A

 

Spencer Rock – Spine board, green

 

ST02112B  Rock Pin Max – Spine board with pins, orange 

ST02033A

 

Spencer Rock – Spine board, red

 

ST02113B  Rock Pin Max – Spine board with pins, red 

ST02036A

 

Spencer Rock – Spine board, military

 

ST02114B  Rock Pin Max – Spine board with pins, military 

ST02010B

 

Rock Pin – Spine board with pins, yellow

 

 

 

ST02012B

 

Rock Pin – Spine board with pins, orange

 

 

 

ST02013B

 

Rock Pin – Spine board with pins, red

 

 

 

 

 

 

 

 

 
These basic models could be modified, with reference to codes and/or descriptions 
without any previous notification.  
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Rock

Страница 1: ...on and the final control of the products certified by the notifying body TÜV SÜD Product Service GmbH INDEX General information pag 2 Warnings pag 2 Product description pag 5 Operating instructions pag 6 Maintenance and cleaning pag 10 Accessories and spare parts pag 12 First edition 2001 Rev 2 23 08 18 Spencer Italia s r l Tel 39 0521 541111 Fax 39 0521 541222 e mail info spencer it ...

Страница 2: ...ble for being used if they haven t been contaminated by any particular agents they can be disposed of as normal solid waste otherwise follow the current regulations about demolition in each country 1 6 Labelling Each device has got an identifying label positioned on the device itself and or on the box This label includes information about the manufacturer the product the CE mark the lot number LOT...

Страница 3: ...ce of combustion or inflammable agents Position and adjust the device taking care not to cause any obstruction to rescuers and or any other rescue equipment Attention laboratory testing post production tests instruction manuals cannot always consider every possible scenario for use This means that in some cases the performance of the product could be notable different from results to date obtained...

Страница 4: ...transport of the patient Do not wash the device in the washing machine Do not use drying machines Avoid contact with sharp objects Do not use the device if it is pierced torn frayed or eccessively worn out Make sure before lifting that the operators have a firm grip on the device Avoid pulling the device on rough surfaces Do not lift by crane or other mechanical lifts The device is a spine board f...

Страница 5: ...atility Using the four skids of high density polyethylene Spencer Rock can slip on the steps of the stairs It ensures in all situations a proper safe and secure total immobilization of the spine and of the patient The material and the construction technique confer the Spencer Rock exclusive characteristics rigidity water resistance buoyancy resistance to impact and corrosion X ray homogeneity and ...

Страница 6: ...g to medical devices MEDDEV 2 4 1a b Guideline for the classification of medical devices NB MED 2 5 1 Rec 5 Technical Documentation MEDDEV 2 7 1 Clinical Data UNI EN 14155 Clinical evaluation of the medical devices for human beings Part 2 Clinical evaluation plans UNI EN 1865 1 2010 Directives for stretchers and other patient transport equipment on ambulances 3 6 Environmental conditions Functioni...

Страница 7: ...on behind the patient s head in misaligned position so that at the end of the pronation supination he will be aligned as much as possible to the patient s head Res 2 manually immobilizes the cervical spine with his hands in such a position that they do not become crossed during rotation he slips his hand under the patient s head to get a good grip making sure to move the head as little as possible...

Страница 8: ...e to the pelvis Res 1 places his hands at shoulder and pelvis including the patient s wrist Res 3 places his hands at the side and the femur fig F Res 2 at the head controls the rotation of the patient on the side saying On three One two three At three Res 1 and 3 rotates the patient 90 degrees keeping the entire column immobilized in line they stop at the stop of Res 2 fig G While Res 1 maintains...

Страница 9: ...N Res 1 and 3 one on each side insert the arm in the armpit of the patient grasping the handle of the spine board just above the armpit fig O Res 4 or a bystander puts a foot on the end of the table so that it can not slip Res 1 and 3 are challenging the spine board with the other free hand and the lower to the ground stopping approximately half way to allow the Res 2 officer heads to reposition t...

Страница 10: ...event of a possible disinfection use products that have not solvent or corrosive action on the materials constituting the device Rinse thoroughly with warm water making sure that you have removed all traces of detergent which could degrade or compromise the integrity and durability of the device The use of high pressure water should be avoided Allow to dry thoroughly before storing Drying after wa...

Страница 11: ...and after each use Spencer Italia S r l declines any responsibility for the proper functioning or damages caused to the patient or user by the use of devices not subject to routine maintenance warranty and will void the compliance to the Medical Device Directive 93 42 CEE The replacement or restoration can only be done by the manufacturer or by an authorized service center Use only accessories ori...

Страница 12: ...Set with 3 belts with quick release buckle ST00494B Board Straps STX 494 Set with 3 belts with carabiner SH00111C Super Blue Compact universal head immobilizer SH00201A Spencer Contour Anatomic universal head immobilizer SH00300A Fix Head Advanced universal head immobilizer SH00240A Tango Fix Integrated adult paediatric head immobilizer SH00150A FXA Universal ankle immobilizer SH00151A FXA Pro Ana...

Страница 13: ...y having attended specific training for this device and not for similar products Keep this document at least 10 years from the end of life of the device Operator s name Training date Training method user s manual during service former class etc Trainer Basic training Advanced training ...

Страница 14: ... be modified without any warning and is not to be intended as a commitment on behalf of Spencer Italia S r l Spencer products are exported to many countries and the same identical regulations are not always valid For this reason there could be differences between the description here described and the product actually delivered Spencer continually strives to reach the perfection of all items sold ...

Отзывы: