118158
‐
001
REV.
A
9
OF
20
1.4.3.
Commands
1.4.3.1.
Set
KV
(10)
This
command
programs
a
new
voltage
set
point
for
the
unit.
This
command
works
in
remote
mode
only.
Input
range
is
0
to
4095.
Maximum
KV
equals
4095.
Example:
set
KV
to
1024
Sent
to
Unit
<STX>10,1024,<ETX>
Received
from
unit
<STX>10,$,<ETX>
1.4.3.2.
Set
mA
(11)
This
command
programs
a
new
current
set
point
for
the
unit.
This
command
works
in
remote
mode
only.
Input
range
is
0
to
4095.
Maximum
mA
equals
4095.
Example:
set
mA
to
1024
Sent
to
Unit
<STX>11,1024,<ETX>
Received
from
unit
<STX>11,$,<ETX>
1.4.3.3.
Get
KV
(14)
This
command
requests
the
unit
return
the
voltage
set
point.
Input
range
is
0
to
4095.
Maximum
KV
equal
4095.
Example:
get
KV
set
point
Sent
to
Unit
<STX>14,<ETX>
Received
from
unit
<STX>14,1024,<ETX>
1.4.3.4.
Get
mA
(15)
This
command
requests
the
unit
return
the
current
set
point.
Input
range
is:
0
to
4095.
Maximum
mA
equals
4095.
Example:
get
mA
set
point
Sent
to
Unit
<STX>15,<ETX>
Received
from
unit
<STX>15,1024,<ETX>