EPM/SMS MANUAL
4
118026-001 REV K
PIN
FUNCTION
1
Ground
2
+28Vdc
3
High Voltage Enable/Inhibit
4
Voltage Test Point: 10V±2% = 0 to Rated
Output
5
Current Test Point: 10V±2% = 0 to Rated
Output
6
Voltage Programming
7
Current Programming
8
+10.24Vdc Reference
9
Program and Test Point Return
Note: If Enable/Inhibit is not used, connect Pin 3 to Pin 8.
Remote Programming:
Permits remote adjustment of the output voltage
and current via an external voltage source. By
adjusting the voltage source from 0V to 10V the
desired output may be selected.
Remote Monitor:
Test points, pins 4 and 5 of the input connector,
monitor voltage and current outputs. The output
polarity is positive from 0V to 10V equal to 0 to
100% of the output ±0.5%. Output impedance is
1k Ohms.
High Voltage Enable/Inhibit:
Control signal which allows the user to inhibit
the power supply output without switching the
HIGH VOLTAGE OFF. See Figures 3.7A and
3.7B.
Figure 2.1 EPM Module Dimensions