background image

PRESET
TEMPERATURE
indicator

Vacation hold & comfortable
hour indicator / current PROG
indicator

Set Mode indicator

Current PROG
INDICATOR

Current system mode

Current mode
indicator

Day of the week

Time display

FAN control option

Room temperature display

24H FORMAT

DAY

COMF.

HOLD

HEAT

COOL

TEMP SET

This particular thermostat is a programmable model. It has a built-in clock
and can change its temperature settings automatically throughout the day.
This has the advantage of ensuring that the temperature in your home is set
to optimum efficiency at all times.

For example, during the winter months you may wish to set your heating
system to warm up the room to 21°C. This is a comfortable temperature in
the house when you are at home. However, it would waste a lot of electricity
to maintain that temperature all day when you are out.

With a programmable thermostat you can set the temperature back, e.g. to
16 C while you are out, and to 18 C at night while you are asleep and still
maintain a comfortable temperature level during the times that you are
relaxing at home.

An efficient heating system should "kick in", or cycle, four to six times per
hour while maintaining one set temperature. However, if the temperature has
been set back to a lower level, the heating system will have to run longer to
recover to the comfort level.

°

°

The question here is: how many degrees can you set the temperature back
to keep the heating from cycling when you don't need it, and still be able to
bring the temperature back up to your comfort level without the heating
system having to run excessively?

Many factors will affect this balance: How big is the difference between
outside and inside temperatures? How large is your house? How powerful is
your heating system? How well is your house / your floor insulated? How
long and at what times are you away from home? How many hours do you
sleep and at what times?

The pre-programmed times and temperatures within your thermostat can
be adjusted to suit your needs. Please read the section on the next few
pages for more information on how to achieve this.

2) Mode

which sets individual programmes for each day of the week.

Once the power is connected the LCD SCREEN will show all symbols for 5
seconds. Thereafter, the LCD SCREEN will display "5:2d" (default). You
can now press the "NEXT" button to select "7d”.

Pressing the “NEXT” button toggles between "5:2d" and "7d".

"7d"

Pre-programmed Times & Temperatures

FACTORY PRESET TIME/TEMPERATURE PROGRAMME

MON, TUE, WED, THU, FRI

SATURDAY

SUNDAY

P1

P1

P1

P2

P2

P2

P3

P3

P3

P4

P4

P4

P5

P6

TIME

TIME

TIME

06:00

07:00

07:00

08:30

08:30

08:30

12:00

16:30

16:30

14:00

22:30

22:30

16:30

22:30

TEMPERATURE

TEMPERATURE

TEMPERATURE

21°C

21°C

21°C

16°C

21°C

21°C

21°C

21°C

21°C

16°C

18°C

16°C

21°C

18°C

After selecting the 5:2d or 7d mode, press the
key or wait for 10 seconds, the thermostat will
then set the day and time to SUNDAY (Day 7),
0:00 and display the room temperature.

9. FLOOR TEMPERATURE SENSOR (OPTIONAL).

10. MODE OF OPERATION SELECTION

The floor sensor should be installed exactly in between two runs of the
heating element and taped / glued down. The sensor is necessary to
prevent overheating of sensitive flooring (wood, vinyl). The maximum
temperature of the floor surface is determined by the floor covering
manufacturer (typically 27°C).

The floor sensor cable must be connected to terminals 1 and 2. The sensor
cable may be shortened. In case of the thin probe, the green and yellow
wires as well as red and black wires must be crimped together in the
ferrules (supplied with the thin probe) and connected resp. to the terminals
1 & 2. (See 7. WIRING DIAGRAMS).

When installation is complete, fit the thermostat to the base, then reset the
thermostat by pressing the "RESET" button. The thermostat will thereafter
automatically check if the floor sensor is installed and display the room
temperature.

If the floor sensor cable is not installed, the floor temperature detecting
function cannot be used. Whenever the floor sensor cable is installed, reset
the thermostat by pressing the "RESET” button.

In this mode, the thermostat will ignore the floor sensor. The temperature of
the room will determine whether the heating system is on or off.

In this mode, the thermostat will continuously compare the floor and room
temperatures to the preset temperature settings.

Important!

Two modes of operation may be selected:

1. Room temperature controller:

2. Room temperature controller with max. floor temperature limitation:

2

At the initial setting of this thermostat, one of two modes may be selected:

1) Mode

which sets weekdays and weekends (Saturday & Sunday).

"5:2d"

Cooling system
active indicator

Heating system
active indicator

8. FEATURES

HEAT-OFF

switch

Saves programmes in
memory and returns to
normal display

Sets the temperature

Adjusts time and day
of the week

Changes the
programme

Temperature &

vacation HOLD

Set Maximum
FLOOR Temperature

Manual MODE and
comfortable Hours SET

Reset button for
system reset

Easy to read digital
LCD display

HEAT

OFF

NEXT

RESET

COMF.

CLOCK

SET

PROG.

SET

HOLD

FLOOR

SET

Info: Display
programmes

Содержание SH-SmartStat

Страница 1: ...ery important to ensure accurate room temperature measurement Observe the following general rules for best results To avoid electrical shock and to prevent damage to the floor heating and thermostat disconnect the power supply before proceeding with the installation To refit the thermostat body to the base plate hook the body onto the bottom of the base plate see photograph Press both parts togeth...

Страница 2: ...PRESET TIME TEMPERATURE PROGRAMME MON TUE WED THU FRI SATURDAY SUNDAY P1 P1 P1 P2 P2 P2 P3 P3 P3 P4 P4 P4 P5 P6 TIME TIME TIME 06 00 07 00 07 00 08 30 08 30 08 30 12 00 16 30 16 30 14 00 22 30 22 30 16 30 22 30 TEMPERATURE TEMPERATURE TEMPERATURE 21 C 21 C 21 C 16 C 21 C 21 C 21 C 21 C 21 C 16 C 18 C 16 C 21 C 18 C After selecting the 5 2d or 7d mode press the key or wait for 10 seconds the thermo...

Страница 3: ...frequently Your thermostat is factory preset to allow the room temperature to rise 0 25 C above the Set Temperature and then it will let it drop 0 25 C below the Set Temperature 0 5 C differential This differential can be changed from 0 5 C to 1 0 C in which case the thermostat will switch less frequently Example it s cold outside and the heating unit is running It has raised the room temperature ...

Страница 4: ...q The Override indicator will display in the top right hand corner After approx 10 seconds the thermostat will start running in Temporary Override mode The Rotary Time Display will show the selected time under Temporary Override mode The present time block will start flashing If the time remaining until the next programme period is not practical for your needs e g you have visitors and the house i...

Отзывы: