Step 6: Plug in the Washer
Washer requires 120 Volt, 60 Hertz electrical supply
and comes equipped with a 3-Prong grounding plug.
Refer to serial plate for specific electrical
requirements.
When plugging in the washer:
•
DO NOT overload circuits.
•
DO NOT use an extension cord.
•
DO NOT use an adapter.
•
DO NOT operate both a washer and gas dryer on
the same circuit. Use separately fused 15 Amp
circuits.
The washer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a
15 Amp fuse
, equivalent fusetron or
circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to
Figure 13
to determine correct polarity of the wall receptacle.
DRY2022N
1
L1
2
Ground
3
Neutral Side
4
Round Grounding Prong
5
Neutral
Figure 13
1
2
3
4
5
Standard 120 Volt, 60 Hertz
3-Wire Effectively
Grounded Circuit
0 V.A.C.
120±12
V.A.C.
120±12
V.A.C.
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA No. 70, and such local
regulations as might apply. It is the
customer’s responsibility to have the
wiring, fuses and circuit breakers
installed by a qualified electrician to make
sure adequate electrical power is
available to the washer.
W518
WARNING
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
electric power source.
W082
WARNING