background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

201471

4

Step 3: Connect Fill Hoses

Water Supply

Water supply faucets must fit standard 3/4 inch 

(19.1 mm) female garden hose couplings. DO NOT 

USE SLIP-ON OR CLAMP-ON CONNECTIONS.
Water supply faucets should be readily accessible to 

permit turning them off when washer is not being 

used.
Recommended cold water temperature is 50

to 

75

o

Fahrenheit (10

o

 to 24

o

 Celsius). Recommended 

maximum hot water temperature is 125

o

 Fahrenheit 

(51

o

 Celsius). Warm water is a mixture of hot and cold 

water. Warm water temperature is dependent upon 

water temperature and pressure of both the hot and 

cold water supply lines.

Water pressure must be a minimum of 20 to a 

maximum of 120 pounds per square inch (138 to 

827 kPa) static pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per 

square inch (138 kPa) will cause an extended fill 

time in the washer.

Turn on the water faucets and flush the lines for 

approximately two minutes to remove any foreign 

material that could clog the screens in the water 

mixing valve.

NOTE: When installing in newly constructed or 

renovated buildings, it is very important to flush 

the lines since build-up may have occurred during 

construction.

Connecting Hoses

Remove the two plain rubber washers and two filter 

screens from the accessories bag. Install them into 

each end of the fill hoses as shown in 

Figure 5

. The 

screen must be facing outward.
Screw hose couplings with the filter screens onto the 

water faucets until they are finger-tight. Then, using a 

pliers, screw approximately 1/4 turn. Use the red 

color-coded hose for the hot water connection and the 

blue color-coded hose for the cold water connection.
Screw hose couplings from other end of hoses onto the 

water mixing valve until they are finger-tight. Then, 

using a pliers, screw approximately 1/4 turn. Refer to 

Figure 6

. Make sure the red color-coded hose from the 

hot water faucet goes to the water mixing valve 

marked “H” and the blue color-coded hose from the 

cold faucet goes to the valve marked “C”.

 

IMPORTANT: Do not cross thread or overtighten 

couplings. This will cause them to leak.

Turn water on and check for leaks. If leaks are found, 

turn off the water, unscrew hoses and reinstall them 

until there are no leaks. 

IMPORTANT: Turn off water supply whenever 

there will be an extended period of non-use.

Mixing Valve Flow Rates (Gallons per Minute)

Hot

Cold

Warm 

(40% Hot)

35 psi

2.4

4.5

7.15

55 psi

3.5

6.2

9.2

Table 1 

Under certain conditions, hydrogen gas 

may be produced in a hot water system 

that has not been used for two weeks or 

more. HYDROGEN GAS IS EXPLOSIVE. If 

the hot water system has not been used 

for such a period and before using the 

washer, turn on all hot water faucets and 

let the water flow from each for several 

minutes. This will release any 

accumulated hydrogen gas. The gas is 

flammable. Do not smoke or use an open 

flame during this time.

W029

WARNING

To prevent personal injury, avoid contact 

with inlet water temperatures higher than 

125

°

 Fahrenheit (51

°

 Celsius) and hot 

surfaces.

W748

WARNING

Содержание Topload Washers

Страница 1: ...hine changes ownership this manual must accompany machine www speedqueen com Installation Instructions for Topload Washers Washer Dimensions 2 Before You Start 2 Installation 3 Installer Checklist Bac...

Страница 2: ...Installation Instructions User s Guide Warranty Bond NOTE If the washer is delivered on a cold day below freezing or is stored in an unheated room or area during the cold months do not attempt to oper...

Страница 3: ...o front or sides when moving Save the shipping brace and plug They must be reinstalled whenever washer is moved or transported to a new location This will prevent damage to the washer Refer to the Use...

Страница 4: ...outward Screw hose couplings with the filter screens onto the water faucets until they are finger tight Then using a pliers screw approximately 1 4 turn Use the red color coded hose for the hot water...

Страница 5: ...handling a minimum of 1 1 4 inch 32 cm outside diameter drain hose Standpipe Installation Place the adapter into the standpipe The recommended height for the standpipe is 36 inches 91 44 cm Standpipes...

Страница 6: ...using the beaded strap from accessories bag Refer to Figure 9 NOTE End of drain hose must be below height of cabinet top Laundry Tub Installation For this type of installation the drain hose MUST be s...

Страница 7: ...level tilt washer back to access the front leveling legs Loosen the locknuts and adjust legs by screwing into or out of washer base Once adjusted tilt the washer forward on front legs and lower back...

Страница 8: ...ectly into a polarized three slot effectively grounded receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 13 to determine correct polarity of the wall receptacle DRY2022N 1...

Страница 9: ...ect the problem NOTE The wiring diagram is located in the control hood Step 7 Add Water to the Washer To prevent damage to pump do not run washer before adding at least one quart water to the tub If t...

Страница 10: ...Washer should stop agitating and spinning when lid is opened Step 9 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctly Ru...

Страница 11: ......

Страница 12: ...Inside of Washtub 2 CHECK TLW2009N TLW2009N Connect Fill Hoses TLW1988N HOT COLD C H 3 CHECK TLW1988N Filter Screens Cold Valve Connection Hot Valve Connection Plain Washers Red Blue Connect Drain Ho...

Отзывы: