9. Place front panel on machine, loosely attach four 

bottom screws. Connect door switch harness to 
switch in new location. Install door assembly and 
four front panel side screws loosely. Refer to 

Figure 9

.

10. Check lint panel fit, adjusting front panel up or 

down as required. Tighten four front panel side 
screws to maintain position of front panel for 
proper lint panel clearance.

11. Remove lint panel. Fully tighten bottom screws 

on front panel.

12. Reinstall top screws and guide lugs.

13. Adjust door catch if necessary to allow 

7 – 15 pounds pull (0.48 – 1.03 bar) at center of 
handle.

14. Reinstall control assembly using mounting 

screws.

15. Reinstall control panel and lint panel.

IMPORTANT: Restore power to tumbler and test 
for proper operation of loading door switch. 
Tumbler should not start with door open; an 
operating tumbler should stop when door is 
opened.

NOTE: If machine is converted back to right hand 
hinge operation, the door switch harness must be 
rerouted and rebundled with the lint panel switch 
harness. Wire ties must be used to secure harnesses. 
Wire ties (Part No. 55881) can be ordered from 
RSPC.

Figure 9 

TMB1997N

1

Switch (New location)

2

Plug (New location)

3

Door Assembly

4

Side Screw

TMB1997N

1

2

3

4

Содержание AT050E

Страница 1: ...fer to Page 4 for Model Identification TMB795C TMB795C NOTA Para bajar una copia de estas instrucciones en espa ol visite www comlaundry com Part No M414905R11 August 2008 Keep These Instructions for...

Страница 2: ......

Страница 3: ...ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your buil...

Страница 4: ...6 Pre Installation Inspection 16 Location Requirements 17 Position and Level the Tumbler 18 Bolt On Angle Option 18 To Reverse the Loading Door 20 Before Placing Tumbler into Service 23 Required for C...

Страница 5: ...Ready Mode 50 Start Mode 50 Run Mode 50 Setting Dry Time Dipswitches 50 Dipswitch Settings 51 Rotary Coin Drop Timer 53 Installing Accessory Timing Cam 53 Removal of Existing Timing Cam 53 Installatio...

Страница 6: ...50T UT050S UT050T UU050S UU050T YT050S YT050T AT050E CHD50E2 CT050E CHD50E2 CU050E DR55E2 BT050E DR55E2 BU050E GT050E GU050E HT050E HU050E IPD50E2 IT050E ST050E SU050E UT050E UU050E YT050E 75 Pound AT...

Страница 7: ...ual timer RT reversing manual timer BL basic electronic central pay NC NetMaster coin SD single drop BU basic electronic prep card open NR NetMaster card SX single drop prep for coin BX basic electron...

Страница 8: ...rical data on the serial plate Serial Plate Location When calling or writing for information about your product be sure to mention model and serial numbers Model and serial numbers are found on serial...

Страница 9: ...ppearing in this manual are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and carefulness are factors which CANNOT be built i...

Страница 10: ...sonnel 15 If not installed operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could exp...

Страница 11: ...w the fabric care instructions supplied by the garment manufacturer 27 Never operate the tumbler with any guards and or panels removed 28 DO NOT operate the tumbler if it is smoking grinding has missi...

Страница 12: ...50 22 7 75 34 75 34 Air Outlet Diameter Inches mm 8 203 8 203 10 254 Maximum Static Back Pressure W C I mbar 0 5 1 3 0 5 1 3 0 5 1 3 Maximum Airflow C F M L sec 750 354 Gas Steam 60 Hz 920 434 Gas St...

Страница 13: ...29 5 in 749 mm 50 Pound Steam 30 75 in 781 mm 28 75 in 730 mm 28 25 in 717 mm 33 87 in 860 mm 47 in 1194 mm 80 in 2032 mm 38 625 in 981 mm 33 in 838 mm 29 5 in 749 mm 75 Pound Gas and Electric 30 75...

Страница 14: ...M414905 12 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Exhaust Outlet Locations TMB811N A B C Models A B C 50 75 Pound 5 375 in 137 mm 8 in 203 mm 13 375 in 340 mm F75 6 5 in 165 m...

Страница 15: ...aundry Systems LLC DO NOT COPY or TRANSMIT Gas Connection Locations TMB812N TMB812N A B Models Diameter A B 50 Pound 1 2 in NPT 15 5 in 394 mm 65 75 in 1670 mm 75 Pound 1 2 in NPT 15 75 in 400 mm 65 7...

Страница 16: ...undry Systems LLC DO NOT COPY or TRANSMIT Electrical Connection Locations TMB813N TMB813N GAS AND STEAM ELECTRIC A B B A Models A B Gas and Steam 9 5 in 241 mm 63 5 in 1613 mm Electric 19 in 483 mm 64...

Страница 17: ...M414905 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Steam Connection Locations TMB814N TMB814N C A B D Models Diameter A B C D 50 75 Pound 3 4 in NPT 15 25 in 387 mm 72 75 in 1848 m...

Страница 18: ...al building codes water supply regulations electrical wiring regulations and any other relevant statutory regulations Due to varied requirements applicable local codes should be thoroughly understood...

Страница 19: ...earance for servicing and operation refer to Figure 1 Figure 1 WARNING To reduce the risk of serious injury install lockable door s to prevent public access to rear of tumblers W055 TMB2131N NOTE Shad...

Страница 20: ...ing legs with nuts previously installed NOTE The front of the tumbler should be slightly higher than the rear approximately 0 125 inch 3 18 mm This will prevent the clothes while tumbling from wearing...

Страница 21: ...ertical trunnion channels 12 Remove the junction contactor box Refer to Figure 4 13 Remove the exhaust thimble 14 The gas supply line may require removal if it extends past the rear panel If so discon...

Страница 22: ...inge assembly securely to prevent it from dropping once side screws are removed from door hinge lug Figure 6 WARNING To reduce the risk of electric shock fire explosion serious injury or death Disconn...

Страница 23: ...button toward center of machine Reinstall plug in switch s previous location Refer to Figure 7 Figure 7 7 Cut wire ties along right side of machine to remove door switch harness from lint panel switc...

Страница 24: ...screws and guide lugs 13 Adjust door catch if necessary to allow 7 15 pounds pull 0 48 1 03 bar at center of handle 14 Reinstall control assembly using mounting screws 15 Reinstall control panel and l...

Страница 25: ...rom the gas lines To reset open and close the loading door and restart tumbler If lockout condition persists check that the manual gas shut off valve is in the ON position and that the gas service is...

Страница 26: ...etroleum L P Gas not regulated no governor Machines configured for Natural Gas regulator governor may be converted to L P Gas not regulated no governor with block open kit Part No M400763 Serial plate...

Страница 27: ...075 3 7 3 6 2 3 M401000 M401014 L P Gas B P 30 No Governor 050 075 2 1 2 0 2 3 M401003 M400999 B P 50 28 5 050 075 2 1 2 0 2 3 M401003 M400999 NL Natural Gas L 25 12 6 050 075 3 7 3 6 2 3 M401000 M40...

Страница 28: ...ith machine and apply it to the serial plate over the ADJUSTED FOR ______ GAS ______ information 5 Commission tumbler for use Figure 11 Specific Conversion Procedures How to Convert Gas Valve from Reg...

Страница 29: ...er to Figure 12 3 Install the new correct burner orifice s Refer to Figure 13 and Table 1 Torque each to 9 10 Nm 4 Reinstall spud holder assembly to gas valve making certain burner orifice s are in li...

Страница 30: ...ug from pressure tap 3 Connect a U tube manometer or similar pressure gauge to the burner orifice manifold pressure tap 4 Start tumbler and note pressure once flame is burning Remove regulator cap and...

Страница 31: ...ints do not permit the accumulation of lint DO NOT use plastic or thin foil flexible ducts Use exhaust ducts made of sheet metal or other noncombustible material Use duct tape or pop rivets on all sea...

Страница 32: ...ized according to Figure 16 and Figure 17 This illustration indicates minimum diameters and should be increased if the collector length exceeds 14 feet 4 3 m and two 90 elbows The diameter of a round...

Страница 33: ...t be sized per local codes NOTE Inside of duct must be smooth Do not use sheet metal screws to join sections Consult your local building code for regulations which may also apply TMB2103N 1 Removable...

Страница 34: ...L K J I H G F E D C B A 3 1 2 ONE MANIFOLD ASSEMBLY Duct Station 50 75 Pound F75 8 in 203 mm Duct 10 in 254 mm Duct A 8 in 203 mm 10 in 254 mm B 12 in 305 mm 15 in 381 mm C 15 in 381 mm 18 in 457 mm...

Страница 35: ...K J I CONTINUE TO A CONTINUE TO A TWO MANIFOLD ASSEMBLIES Duct Station 50 75 Pound F75 8 in 203 mm Duct 10 in 254 mm Duct A 13 in 330 mm 15 in 381 mm B 17 in 432 mm 22 in 559 mm C 18 in 457 mm 26 in...

Страница 36: ...e gas service line to each tumbler Refer to Figure 18 Sediment traps Shut off valves Supply pressure taps It is important that equal pressure be maintained at all tumbler gas connections This can be d...

Страница 37: ...these steps until burner ignites Use pipe compound resistant to actions of L P gas on all pipe threads Figure 18 WARNING Check all pipe connections internal and external for gas leaks using a non cor...

Страница 38: ...r each 6 19 ft 5 8 m 75 pound tumblers 165 000 Btu hr each F75 pound tumblers 215 000 Btu hr each SAMPLE CALCULATIONS Equivalent length Total length of main gas supply pipe to the far end of the tumbl...

Страница 39: ...40 1 25 40 1 25 31 75 1 25 31 75 1 5 38 10 1 5 38 10 2 50 80 2 50 80 2 50 80 2 50 80 2 50 80 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 3 76 20 3 76 20 3 76 20 3 76 20 3 76...

Страница 40: ...M401003 91 200 8001 10 000 2441 3050 47 0 0785 2 0 M400999 81 600 75 Pound Natural Gas 2001 4000 610 1220 29 0 1360 3 4 3 M400997 151 800 4001 8000 1221 2440 30 0 1285 3 3 M401021 138 600 8001 10 000...

Страница 41: ...el NOTE Activation of the emergency stop switch stops all machine control circuit functions but DOES NOT remove all electrical power from machine WARNING To reduce the risk of electric shock fire expl...

Страница 42: ...on CE Gas or Steam Non CE Electric CE Gas or Steam CE Electric F U S E FUSE F U S E L1 L2 L3 F T1 T2 T3 Z Y X W V U F R Z Y X W V U F R F U S E FUSE F U S E TMB1274N Ground Screw Terminal Block Juncti...

Страница 43: ...ads to the disconnect switch or circuit breaker Connect the wire leads to the appropriate labeled terminal on the terminal block The ground wire must be connected to the ground connection as shown in...

Страница 44: ...re 21 T224S TMB2017N 1 Electrical Service Gas and Steam Models 6 Ground Screw Gas and Steam Models Only 2 Electrical Service Electric Models 7 Ground Buss Bar 3 Accessory Box 8 Contactor Box 4 Ground...

Страница 45: ...the rear of the tumbler sign and date conversion label to document the conversion Ferrite Ring Installation Gas and Steam OPL Control Models Only The ferrite ring provided in the literature packet mus...

Страница 46: ...re failure of the motor s 7 Serial Plate Rating Terminal Block Connections Required Serial Plate Amps Recommended Circuit Nonreversing Reversing Breaker Rating Wire Size AWG mm2 120V 60Hz 1ph L1 Neutr...

Страница 47: ...Wire Size AWG mm2 120V 60Hz 1ph L1 Neutral and ground 13 8 N A 20A 1 pole 12 3 31 200 208V 60Hz 1ph L1 Neutral and ground 7 6 N A 15A 1 pole 14 2 08 200 208 240V 60Hz 1ph L1 L2 and ground 7 6 N A 15A...

Страница 48: ...ed to its own individual branch circuit breaker not fuses to avoid the possibility of single phasing and causing premature failure of the motor s Serial Plate Rating Terminal Block Connections Require...

Страница 49: ...ll a bypass trap to drain condensate from the low point in the steam header to the return In both steam supply and steam return line it is recommended that each have a pipe union and shut off valve Th...

Страница 50: ...e to each steam trap 5 Connect to the condensate return lines 6 For steam solenoid valve wiring connections refer to Wiring Diagram supplied with tumbler Thermal Oil Prep It is the responsibility of t...

Страница 51: ...ws 1 Supply 8 18 in 457 mm Drop 2 12 in 305 mm Riser 9 Solenoid Valve Supplied with machine 3 Shut Off Valve 10 Steam Bonnet 4 Condensate Return Line from Supply Line 11 Flexible Line 5 Return 12 Unio...

Страница 52: ...ge the dry time on the tumbler combinations of dipswitches can be set on the control There are eight dipswitches on the tumbler control The first six switches are used to program the amount of additio...

Страница 53: ...N OFF OFF OFF 9 OFF OFF OFF ON OFF OFF 10 ON OFF OFF ON OFF OFF 11 OFF ON OFF ON OFF OFF 12 ON ON OFF ON OFF OFF 13 OFF OFF ON ON OFF OFF 14 ON OFF ON ON OFF OFF 15 OFF ON ON ON OFF OFF 16 ON ON ON ON...

Страница 54: ...F ON OFF ON OFF ON 44 ON ON OFF ON OFF ON 45 OFF OFF ON ON OFF ON 46 ON OFF ON ON OFF ON 47 OFF ON ON ON OFF ON 48 ON ON ON ON OFF ON 49 OFF OFF OFF OFF ON ON 50 ON OFF OFF OFF ON ON 51 OFF ON OFF OFF...

Страница 55: ...tch clears the ratchet tooth Installation of New Timing Cam 1 Insert drive fork into timing cam with wide prong in wide hole of cam 2 Position timing cam and drive fork over the timer shaft aligning t...

Страница 56: ...ame pattern that flares to the right and left indicates no air is flowing through the tumbler Correct air and gas mixture is indicated if the flame pattern is primarily blue with small yellow tips and...

Страница 57: ...person opening lint panel in front and another adjusting the counterweight in the rear of tumbler 2 Temporarily tape down the lint panel safety switch located behind the upper right corner of the lin...

Страница 58: ...ystems LLC DO NOT COPY or TRANSMIT Figure 26 T041I 1 Airflow Switch 6 Switch Lever 2 Mounting Bracket 7 Spring Clip 3 Rear Panel of Tumbler 8 Counterweight 4 Switch Mounting Screws 9 Disc 5 Screw 10 V...

Страница 59: ...roper belt tension is reached then retighten idler housing bolts 4 Replace the guard on rear of tumbler Reversing Models Refer to Figure 29 Proper tension is when the drive belt can be depressed appro...

Страница 60: ...yright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Figure 28 TMB816N 1 Poly V Belt Self Adjusting 4 Drive V Belt 2 Idler Housing Bolts 2 5 Idler Housing Assembly 3 Adjusting Bolt TMB816N NONR...

Страница 61: ...undry Systems LLC DO NOT COPY or TRANSMIT Figure 29 TMB817N 1 Locking Bolt 5 Guide Rail 2 Adjusting Nut 6 Idler Housing Bolts 2 3 Adjusting Screw 7 Adjusting Bolt Not shown 4 Cylinder Belts 8 Drive Be...

Страница 62: ...removed from service perform the following steps where applicable Turn off electrical supply external to machine Turn off electrical disconnect on machine Turn off gas supply external to machine Turn...