Spectrum Freedom XRS Elite Скачать руководство пользователя страница 16

0118857 Page 16 of 18

Description of the DESKLINE® DL5/DL6 system

Each DESKLINE®  DL5/DL6 lifting units is equipped  with a motor and parallel/memory  

drive is ensured by means of software in the CBD4/CBD5/CBD6 that also takes account 

of oblique load on the desk. Soft start and stop are also part of this software, which 

ensures a soft start and stop when adjusting the desk.

Application of the DESKLINE® DL5/DL6 system:

Irrespective of the load the 

duty cycle 10% ~ 6 min./ hour or max. 2 min. at 

continuous use

 stated in the data sheets, must 

NOT

 be exceeded as this will result 

in a superheating of the motor, the brake and the spindle nut. Exceeding the duty cycle 

will result in a dramatic reduction of the life of the system.
The DESKLINE®  DL5/DL6 system range contains the following products:

•  1 control box CBD4/CBD5/CBD6

•  1 single DL5/DL6 or 2, 3, or 4 parallel

•  1 exchangeable mains cable

•  1, 2, 3, or 4 motor cables

•  1 DP1U/DPF1M (if memory function is required)  DP1C/WDPL/DPT/DPF1C (if 

memory function and display is required) or 1 DPA/DPB/DP1K/DP1V/DPF1K (if only 

up/down is required.)

Anti-Collision™

The function (anti-collision)  is an option for the standard CBD4/CBD5/CBD6 advanced/

control box software 0077432 version 1.66 and later. A system with anti-collision can limit 

material damages on a desk if a collision with a solid object should occur

Method of operation

When the DL/DB’s are running the CBD4/CBD5/CBD6 monitors the current 

consumption on each channel using a special algorithm. If the current consumption 

on one channel is increased more than a predefi ned slope, a collision is assumed and 

all channels are stopped immediately and all DL/DB’s will start to run in the opposite 

direction (approx. 50 mm). This return drive is done automatically and continues with 

or without any control key pressed (for max. 2.5 sec.).
The anti-collision  sensitivity is different in upward and downward direction. Upwards 

the force is approx. 20 kg. Downwards the load will be approx. 40 kg + the load on the 

DL/DB (the desk + what is on top of the desk). The 40 kg are needed to activate the 

anti-collision function.

Situations where the anti-collision does not work

There are situations where the anti-collision will not be activated. These situations are:

•  If the collision happens during the initialisation phase

• 

If the collision happens within the fi rst 1000 msec or after the control button has 

been released

• 

If the collision happens between the fl oor and the table and the load on the desk + 

the weight of the legs are lower than 40 kg

•  If the collision happens over too long time, e.g. if the collision is with a soft object.

Misc. on the DESKLINE® DL5/DL6 system

This system is a DESKLINE system developed for desks and for indoor use in offi ces. Do not 

use it in industrial kitchens or in other enviroments that have to be cleaned with aggressive 

detergents.  Do not bolt the legs to the fl oor so that free movement is prevented. This could 

cause serious damage to the legs in fault situations.

Warranty

There is a 36 months’ warranty on the DESKLINE products against manufacturing faults 

from the production date of the individual products (see label).

LINAK A/S’ warranty is only valid in so far as the equipment has been used and main-

tained correctly and has not been tampered with. Furthermore, the system must not be 

exposed to violent treatment. In the event of this,

the warranty will be ineffective/invalid. For further details, please see LINAK A/S ordinary 

conditions of sale.

Maintenance

Clean dust and dirt on the outside of the system at appropriate intervals and inspect them 

for damage and breaks.  Inspect the connections, cables, and plugs and check for correct 

functioning as well as fi xing points.

Service of double-insulated products:
Class II

A Class II or 

double insulated

 electrical appliance is one which has been designed in 

such a way that it does not require a safety connection to electrical earth (US: ground).
The basic requirement is that no single failure can result in dangerous voltage becoming 

exposed so that it might cause an electric shock and that this is achieved without relying 

on an earthed metal casing. This is usually achieved at least in part by having two layers of 

insulating material surrounding live parts or by using reinforced insulation.

There is no earthing/grounding means provided on the product, and no earthing/ground-

ing means is to be added to the product.
In Europe, a double insulated appliance must be labelled “Class II”, “double insulated” or 

bear the double insulation symbol (a square inside another square).

Servicing a double-insulated product requires extreme care and knowledge of the system, 

and is to be done only by qualifi ed service personnel. Replacement parts for a double-in-

sulated product must be identical to the parts they replace.

The cleaners and disinfectants must not be highly alkaline or 

acidic (pH value 6-8).

Electrical connection of the DL5/DL6 system

The DESKLINE® DL5/DL6 system is to be connected as shown on fi gure 4. Each DL5/

DL6 is to be connected to the sockets on the control box by means of the motor cables, 

which have an 6-pin plug in each end.  Finally, the mains cable is to be mounted and 

power switched on.

Please note that the control box must only be connected to the voltage stated on the 

label.

CBD4/CBD5/CBD6 with earth

The CBD4/CBD5/CBD6 earth cable to be mounted on the desk construction (typically the top 

frame) in a way that ensures good electrical contact. The function of the earth cable is to earth 

the desk and ground static electricity. The earth connection does not protect other electrical 

products.

CBD4/CBD5 with mains cut-off (non ZERO models)

If the power cable is damaged it has to be replaced by an authorized LINAK 

service centre to avoid any danger.

DL5/DL6 cable

DL5/DL6

hook for cable relief

main 

cable

DL5/DL6

DP/WDPL

Содержание Freedom XRS Elite

Страница 1: ...to purchase parts or accessories or if you have any questions please contact us Thank you for purchasing Spectrum products Spectrum Industries Inc 925 First Avenue Chippewa Falls WI 54729 USA 800 235 1262 715 723 6750 www spectrumfurniture com XRS Elite with surround keyboard tray and rack cabinet installed on left shown retracted XRS Elite with overbridge keyboard tray and rack cabinet installed ...

Страница 2: ...d from electrical outlet by gripping the cord Do not unplug the power cord by pulling only on the cord Do not step on drive over drag or place objects on the power cord For added safety plug the lectern into a grounded outlet controlled by a GFI Ground Fault Interrupter circuit breaker Electrical devices are not toys Children are often unaware of the hazards associated with electrical devices This...

Страница 3: ...tern off the pallet 5 Remove cardboard sleeve by lifting it up and over the lectern 6 Remove protective shrink wrap from lectern using a utility knife scissor or other tool Be careful not to damage the lectern when cutting shrink wrap 7 Remove Styrofoam corner blocks 8 Using ramp carefully lower the lectern off the pallet onto the floor Note Upon receiving lectern inspect packaging for damage To r...

Страница 4: ...tion when raising or lowering the worksurface Preparation Read all instructions before operation Make sure lectern is plugged in using the 15 foot 15 amp power cord Locate the Up and Down control buttons Control pad is located on the instructor side under the worksurface front edge on opposite side from rack cabinet Keep clear of pinch points during worksurface movement Normal Operation To raise o...

Страница 5: ...o the 2 keyhole slots Figure 3B 4 Pull the skirt back toward audience side to lock the screws into the keyhole slots The short flat skirt edge should contact the audience side skirt 5 Apre installed magnet on each skirt will secure the assembly to the lectern base Make sure the magnet on each side skirt is fully seated and contacting the base Each skirt should be level Figure 3C Figure 3C Left sid...

Страница 6: ...binet 1 To detach the rack cabinet from the lectern unlock the cabinet lock pawl near the floor Figure 4B 2 Slide the cabinet toward the center of the lectern to release the cabinet from the keyhole slots Rack cabinet shown on right side of lectern Docking Cabinet 1 To secure the rack cabinet to the lectern position the cabinet on the left or right side of the lectern 2 Engage the keyhole slots an...

Страница 7: ...f the shelf Use of the shelf grommet hole for wiring will result in pinching of the cords when the shelf is folded CAUTION Keep clear of pinch points during shelf movement Do not exceed 50 lb 22 68 kg of weight on shelf Operation The shelf will automatically lock into place when lifted into the horizontal position with the levers released Figure 6A To lower or flip up the shelf press and hold the ...

Страница 8: ...e making sure all devices fit within the maximum cutout space available in the overbridge panel See Figure 7B 7C See specifications for cutout clearances B Locate and mark the exact cutout area s on the panel Note Using masking tape on cut lines will minimize laminate chipping while cutting C Carefully make the cutout s in the overbridge panel using a jigsaw or router 3 Install controller s electr...

Страница 9: ...rum to ensure clearance of brackets keyboard slides or other objects under the worksurface Contact Spectrum to specify cutout size s and location s Wiring Channel 2 Grommet Max cutout area 2 Grommet Overbridge Section view B B Worksurface opening below Worksurface Freedom XRS Elite Lectern overbridge insert panel blank flat view 0118857 Page 9 of 18 Figure 7B Figure 7C ...

Страница 10: ...ntrol box To wall outlet Figure 8A Actuator Control box Note A separate power strip is recommend ed not included to plug the control box and other power plugs into The power strip can be located in the cord channel or lower side of the lectern and plugged into a wall outlet Actuator Note Power cord can be plugged into a power strip not included inside lectern 0118857 Page 10 of 18 ...

Страница 11: ... enough slack in the cords and wires from the rack cabinet to pull the rack cabinet out from the lectern Cords and wires from Rack Cabinet Rack Cabinet 0118857 Page 11 of 18 Bottom view 2 Grommets for floor power access Rack cabinet ...

Страница 12: ...ower cords across hallways classrooms or other areas where they will be walked on Do not leave unit unattended in areas where children have access Keep doors closed and locked whenever unit is unattended or parked Keep casters locked whenever the lectern is unattended Caster operation Figure 9 1 Lock the brake levers to lock movement of the casters Two instructor side casters only Figure 9 2 To re...

Страница 13: ... 20 6 W 52 3 cm x 27 3 D 69 3 cm x 28 8 H 73 2 cm Unit weight 65 lb 29 5 kg Keyboard Tray 55334 Installed in left or right position opposite rack cabinet using pre drilled holes Tray can be installed and used as a keyboard tray or flipped and used as a storage drawer using pre drilled mounting holes under the worksurface Wire management slots in tray Max 1 tray per Freedom XRS Elite Customer insta...

Страница 14: ...2 grommets with covers Customer installed Cove Power Module 99044 Two power receptacles Two USB charge ports not data compatible Thumbscrew clamps Requires worksurface cutout ETL listed Customer installed Cutout required 5 25 W 13 3 cm x 2 D 5 1 cm mounts to surface thicknesses up to 1 5 Power cord 9 274 cm with 90 flat plug with 45 rotation Power receptacles 12A 120 VAC spill resistant USB chargi...

Страница 15: ... instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product It is the operator s responsibility to ensure that there is free space for the application to move without risk for the operator or bystanders before operating the application Misuse Do not overload the ...

Страница 16: ... cleaned with aggressive detergents Do not bolt the legs to the floor so that free movement is prevented This could cause serious damage to the legs in fault situations Warranty There is a 36 months warranty on the DESKLINE products against manufacturing faults from the production date of the individual products see label LINAK A S warranty is only valid in so far as the equipment has been used and...

Страница 17: ... the up button 2 Remove any items under the lectern worksurface 3 Reset the lift mechanism see below for procedure Misaligned actuators due to unbalanced loads Solution 1 Reset Procedure 1 Unplug then re plug the power cord into a wall outlet 2 Make sure all lift mechanism wire connections are in place and secure 3 Remove anything located under the lectern worksurface 4 Press and hold the Down but...

Страница 18: ...TORT OR OTHERWISE EXCEED THE PURCHASE PRICE RECEIVED BY SPECTRUM FOR THE PRODUCT AT ISSUE AND RECALLACTION EXPENSES SPECTRUM SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARIS ING OUT OF BREACH OF CONTRACT WARRANTY TORT INCLUDING NEGLIGENCE AND STRICT LIABILITY OR OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD OR SERVICES RENDERED BY SPECTRUM OR ANY UNDERTAKINGS ACTS OR...

Отзывы: