Spectrum Industries Freedom One eLift Lectern Скачать руководство пользователя страница 3

0118408 Page 3 of 16

Figure 3.2

(2) 1/4-20 

x 15mm JC 

bolts

(4) 1/4-20 x 40mm 

JC bolts

1.  Determine which side of the lectern the equipment rack is to be installed (left 

or right side).  (Right-side installation shown.)

2.  Attach the unit-to-unit brackets to the equipment rack side panel mounting 

holes with (4) 1/4-20 x 15mm JC bolts.  

Figure 3.1

.

Figure 3.1

Unit-to-Unit bracket

(2) 1/4-20 x 

15mm JC bolts

Unit-to-Unit bracket

Lectern

Equipment Rack with 

installed unit-to-unit 

brackets

3.  Bring the equipment rack to the lectern and align the unit-to-unit 

brackets with the mounting holes in the lectern leg.

4.  Install (4) 1/4-20 x 40mm JC bolts through the top of the 

lectern leg and tighten securely.  

Figure 3.2

.

Equipment Rack

Lectern leg

4

mm

Note: The flip-up shelf option may not be included with all configurations.  

The shelf is designed for use on Freedom One eLift equipment racks that 

are attached to the lectern with unit-to-unit connectors.  The shelf installs 

on the equipment rack side opposite the Freedom One Lectern.  

Figure 4.2

Figure 4.1

Folding shelf 

bracket

Release lever 

(press here)

1. 

Determine which side of the equipment rack you want the shelf installed.  

(Left or right).

2. 

Extend each shelf bracket by depressing the release lever and lifting 

until it locks into the 90° position. 

Figure 4.1

.

3.  Using a second person to support the shelf, install the (8) 8-32 x 1/2” PH 

thread-cutting screws into the side panel.  Do not tighten until all screws 

have been installed.

4. 

Tighten all screws securely.

5.  Install 2” grommet.

Equipment Rack

Flip-up shelf 

assembly

2” Grommet

8-32 x 1/2” PH

thread-cutting screws

(4 per bracket)

CAUTION

Keep clear of pinch points during shelf movement.  Do not exceed 35 lb 

[15.9 kg] of weight on shelf.  

Not for use on stand-alone equipment racks.

Operation

The shelf will automatically lock into place when lifted into the horizontal 

position with the levers released.  

Figure 4.2

.  To lower or flip-up the shelf, 

press and hold the shelf bracket levers while slowly lowering or raising the 

shelf.  Do not move the lectern while the shelf is in the horizontal position.
Note:  Power and communication wiring for document cameras, laptop 

computers, and / or projectors placed on the flip-up shelf should be routed 

on top of the audience-side of the shelf.  Use of the shelf grommet hole for 

wiring will result in pinching of the cords when the shelf is folded.

Installing flip-up shelf 

(optional)

3.  Connect lectern and equipment rack

Содержание Freedom One eLift Lectern

Страница 1: ...ntactus Thank you for purchasing Spectrum products Lespi cesendommag espendantletransportdoiventfaire l objetd unrapportdansles5joursdeleurr ception Veuillez prendrecontactavecnoussidespi cesmanquento...

Страница 2: ...tern 1 On a non abrasive surface carefully tip the equipment rack onto its back or side 2 Install the included stem casters or glides and tighten securely Note 2 locking casters should be installed on...

Страница 3: ...quipment rack you want the shelf installed Left or right 2 Extend each shelf bracket by depressing the release lever and lifting until it locks into the 90 position Figure 4 1 3 Using a second person...

Страница 4: ...e install the overbridge panel and secure with 2 1 4 20 x 35mm JC bolts Note Blank overbridge panels require the cus tomer to make necessary cutouts with a jigsaw or router This has a moderate difficu...

Страница 5: ...t Overbridge Insert Panel Blank flat view Overbridge section view 2 grommet Max cutout area Cutouts should be avoided here if device will descend below worksurface Actuator plug below worksurface Work...

Страница 6: ...ildren to move Lock the casters after moving Do not park unit in areas of heavy traffic Do not run power cords across hallways classrooms or other areas where they will be walked on Do not leave unit...

Страница 7: ...g weight 27 lb 12 3 kg Unit to Unit Connector Kit 55359 For connecting equipment rack to lectern Simple installation lectern and equipment rack can remain right side up Shipping weight 9 lb 3 9 kg Cus...

Страница 8: ...ceptacles 2 USB charge ports Aluminum housing and flange Thumbscrew clamps Requires worksurface cutout ETL certified Available in black silver or white Customer installed Equipment Rack for Freedom On...

Страница 9: ...rotection Easy customer installation Battery Type Lithium ion Capacity 2 2 Ah 53 Wh Voltage nominal 24V Discharge current 9A max Max charging voltage 40V DC Charging current 0 5 A Certifications EN 62...

Страница 10: ...utout to be made by customer UL certified Dual Flat Panel Monitor Arm 95533 Weight range 3 5 13 lb 1 6 5 9 kg per monitor Six mounting options clamp thru desk wall grommet hole side bolt reverse wall...

Страница 11: ...witch Enhanced surge protection ETL listed UL listed 19 W 48 27 cm x 9 25 D 23 5 cm x 1 74 H 4 41 cm Shipping weight 8 7 lb 3 9 kg 16ga steel Drawer 15 97 W 40 56 cm x 14 56 D 36 98 cm x 3 H 7 63 cm W...

Страница 12: ...o is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product Misuse Do not overload the actuators this can cause dange...

Страница 13: ...e g if the collision is with a soft object Misc on the DESKLINE DL5 DL6 system This system is a DESKLINE system developed for desks and for indoor use in offices Do not use it in industrial kitchens o...

Страница 14: ...he power cord into a wall outlet 2 Make sure all lift mechanism wire connections are in place and secure 3 Remove anything located under the worksurface 4 Press and hold the Down button to lower the w...

Страница 15: ...celui ci Si une maintenance est requise communiquer avec Spectrum Industries pour obtenir de l aide Consignes de s curit en lectricit Ne pas brancher le cordon d alimentation sur une rallonge V rifier...

Страница 16: ...ber spectrumfurniture com register Learn more at Product Registration 1 800 235 1262 Toll free HELPLINE spectrum spectrumfurniture com Warranty We will make it right for you Thanks for choosing Spectr...

Отзывы: