background image

0115715 Page 3 of 3

 

 

925 First Avenue, PO Box 400, Chippewa Falls, WI 54729  Ph:

 800-235-1262, 

715-723-6750  Fax:

 800-335-0473, 

715-738-2309

E-mail:  [email protected]        web:  www.spectrumfurniture.com

3.  Install side worksurfaces

1.  Set the 2 side worksurfaces onto the table and align the mounting holes.  

Figure 3A

.

2.  Attach each side worksurface to the table with (4) 1/4-20 x 2-3/4” PHM screws and tighten securely.

3.  Install a 1/4-20 x 5/8” PHM screw through the remaining hole in each cantilever worksurface bracket and into 

the side worksurface.

4.  Attach each unit-to-unit bracket to the side worksurface with (2) 1/4-20 x 5/8” PHM screws.  

Figure 3B

5.  Line up the edges of the previously installed end worksurfaces with the side worksurfaces.

6.  When everything is aligned and without gaps, tighten all worksurface and unit-to-unit bracket screws securely.

7.  The center console panel can now be installed.

Figure 3A

side worksurface

(install 2nd)

1/4-20 x 2-3/4” PHMS

(4 required per side worksurface)

Phillips 

screwdriver

Tools

 

Required

side worksurface

(install 2nd)

end worksurface

(install 1st)

end worksurface

(install 1st)

1/4-20 x 2-3/4” 

PHMS

dual unit-to-

unit bracket

Figure 3B