Spectrum Illumination MONSTER BRAIN Скачать руководство пользователя страница 1

 

 

 

 

 

MONSTER 

BRAIN 

INSTRUCTION 

MANUAL 

 
 

 

Spectrum Illumination

 

5114 Industrial Park Road  Montague, MI  49437 

Phone 231.894.4590  Fax 231.894.4582 

www.spectrumillumination.com 

 

 

 

Содержание MONSTER BRAIN

Страница 1: ...MONSTER BRAIN INSTRUCTION MANUAL Spectrum Illumination 5114 Industrial Park Road Montague MI 49437 Phone 231 894 4590 Fax 231 894 4582 www spectrumillumination com ...

Страница 2: ...ng 10 For Connection Using Direct Connect Crossover Cable 10 For Connection Using Pre Existing LAN 12 Programming For Your Application 14 Section 5 Setting Parameters with TCP IP 15 Section 6 Setting Product ID with I O 17 Chart for Product ID Binary Count 18 Section 7 Triggering Your Camera with the Monster Brain 19 Section 8 Flash Software Upgrading 20 Section 9 Specifications 22 Section 10 Trou...

Страница 3: ...ed to succeed in the Vision Lighting business we needed to be different Not only different we needed to be better than everyone else We needed to offer better lighting products for more applications at lower prices We now are going into our tenth year of operation and are getting better and more enthusiastic everyday We are coming out with new products all the time and are designing custom lightin...

Страница 4: ... to install just use web browser Ethernet programmable and controllable All parameters can be set via simple ASCII text strings Simple connection to LDM drivers via DIN rail bus 4 separate user configurable channels Controls multiple lights strobe timings and intensity Software is flash upgradable Trigger via high speed wired inputs or through ethernet 2 camera trigger outputs Store up to 63 Produ...

Страница 5: ...esigned to facilitate external input control External strobe inputs can be wired to the driver s input to control light timing DIP switches 1 to 4 must be off while other drivers use the single strobe channel from the Monster Brain Another option would be to run a 0 10 volt analog input into the ALDM drivers DIP switches 5 to 7 must be off that would free up additional strobe channels Multiple Mon...

Страница 6: ...connectors to the right of the Monster Brain s connector and the driver s subsequently 3 Connector wiring Red Connector Power Trigger inputs Pin 1 24VDC input Pin 2 GND 24VDC return Pin 3 NPN trigger input Pin 4 PNP trigger input Blue Connectors Product ID I O section Pin 1 Product ID B0 LSB Pin 2 Product ID B1 Pin 3 Product ID B2 Pin 4 Select Pin 5 Product ID B3 Pin 6 Product ID B4 Pin 7 Product ...

Страница 7: ... Note ensure grounds of all drivers and the Monster Brain are a common ground if all devices are not being run with the same power supply 6 Determine the number of analog bus outputs that are needed Analog drivers are used to vary the output of the light If all of the lights need to be the same intensity then only one 1 analog output channel will be needed However up to three different intensities...

Страница 8: ...drivers being run at the same intensity How many channels for intensity are needed with the Analog Drivers 2 Strobe 2 Analog 1 Strobe 3 Analog Note Purchase Analog Drivers to control the intensity using the Monster Brain Controller Controlling the intensity of your Monster Lights using the Monster Brain Controller Bus Output Configuration NO NO YES YES YES ONLY 1 MORE THAN 1 3 2 ...

Страница 9: ...nnel 3 you would flip switch 6 and switch 1 CAUTION ONLY ONE OF EACH OF THE TYPES OF SWITCHES CAN BE TURNED ON PER DRIVER IF MORE THAN ONE STROBE OR MORE THAN ONE ANALOG SWITCH ARE TURNED ON AT THE SAME TIME THIS COULD CAUSE DAMAGE AND OR FAILURE TO THE PRODUCTS AND OR YOUR EQUIPMENT 12 It is important to remember that with the Monster Brain controller the drivers can be wired to external triggeri...

Страница 10: ...e same time Also any analog drivers with the same analog output switches on will have the same intensity while strobing Below are the allowable DIP switch settings per driver other settings will cause undesired results External No Analog Control Analog Output 1 Analog Output 2 Analog Output 3 External Strobe used N A Strobe Channel 1 Strobe Channel 2 N A Strobe Channel 3 N A N A Strobe Channel 4 N...

Страница 11: ...rossover Cable 1 When attaching Monster Brain directly to a laptop or PC use a Cat5 or higher crossover cable from Monster Brain to computer Ethernet port 2 When connecting two devices with a crossover cable they must be on the same LAN the same sub network and have unique IP addresses 3 In order for your PC or laptop to communicate with the Monster Brain you must change the IP address of your com...

Страница 12: ...te down any information on the properties page if any numbers are currently present before entering any new information Press the use the following IP address button if not already depressed and input 192 168 1 140 in the IP address and 255 255 255 0 in the Subnet mask if not the default Press OK in IP Properties and then press OK in Local Area Connection Properties screens ...

Страница 13: ... address that is not being used NOTE Ensure IT department knows that the default IP address of the Monster Brain is 192 168 1 142 WARNING Spectrum Illumination is not responsible for the loss of information due to not following proper networking procedures 2 If attaching through a network connection use standard Ethernet cable from the Monster Brain to your network connection 3 Run MB Locator prog...

Страница 14: ...Spectrum Illumination Monster Brain Controller Manual 13 Rev Date 2013 11 27 Note If you do not see the programming page please see the troubleshooting section ...

Страница 15: ... programming just applied 7 To ensure proper programming type Product ID number just saved into the Current Product ID box and click Set Go to the bottom of the page and press Trigger to test the operation of all lights at appropriate times Entering a number in the Manual Trigger number field will repeat the product ID that number of times delay will cause a pause between the repeats Note Product ...

Страница 16: ...lure The flash memory limit applies to set poweron id as well Description ASCII Message Example Response Set Operating Product ID set prod id set prod id 5 set prod id OK set prod id ERROR Request Selected Product ID get prod id get prod id prod id 5 Set Power On Product ID set poweron id set poweron id 8 set poweron id OK set poweron id ERROR Request Power On Product ID get poweron id get poweron...

Страница 17: ...igger trigger OK Get Total Triggers get total triggers get total triggers total triggers 5 Get Missed Triggers get missed triggers get missed triggers missed triggers 2 Clear Total Triggers clear total triggers clear total triggers clear total triggers OK Clear Missed Triggers clear missed triggers clear missed triggers clear missed triggers OK Example of get settings prod id 0 bus config 0 strobe...

Страница 18: ...determine which Product ID to run Next bring the appropriate bits as charted on next page to appropriate logic levels Hold these bits then send a logic high to Pin 4 3 The Monster Brain will receive your signal and send an acknowledge signal back to your device from Pin 8 logic low The output will send a pulse train equal to the Product ID 1 i e product ID 11 will result in 12 logic low pulses Not...

Страница 19: ... ID Active Pins for Binary Count Product ID Active Pins for Binary Count 1 2 3 5 6 7 1 2 3 5 6 7 0 32 1 33 2 34 3 35 4 36 5 37 6 38 7 39 8 40 9 41 10 42 11 43 12 44 13 45 14 46 15 47 16 48 17 49 18 50 19 51 20 52 21 53 22 54 23 55 24 56 25 57 26 58 27 59 28 60 29 61 30 62 31 63 Logic High 3 30VDC Blank Logic Low 0 1VDC ...

Страница 20: ...ter Brain is the connections for the camera outputs The camera outputs are illustrated in the chart below 3 Use the Trigger and Camera Outputs web page area for setting the delay on your camera trigger in one 1 millisecond intervals This is how long the delay is after receiving trigger input The camera output delay function allows the Monster Light to turn completely on and stabilize before taking...

Страница 21: ...pdate exe and MonsterBrain_VXXX_APP s19 available at www spectrumillumination com MBC htm 2 Connect Monster Brain to LAN or direct with crossover cable as shown in section 4 3 Run AutoUpdate exe and the image below should be displayed 4 Click on Find 5 Select the SI Monster Brain to be upgraded and click OK 6 Click Browse and locate the MonsterBrain_VXXX_APP s19 file saved earlier ...

Страница 22: ...n Controller Manual 21 Rev Date 2013 11 27 7 Select MonsterBrain_VXXX_APP s19 and click Open 8 Check the box Reboot when complete and click Update 9 The following should be displayed when complete 10 Click OK flash updating is complete ...

Страница 23: ...ns 1 7 10KΩ typical Product ID Input 1 VDC for Logic Low 3 30 VDC for Logic High Product ID output impedance pin 8 4 7KΩ typical Camera Trigger output impedance 2 7KΩ typical 0 10V Output Control 0 0V 100 10V ENVIRONMENTAL Operating Temperature 0 to 50 C Relative Humidity 5 to 85 non condensing MECHANICAL Connectors Connector with screw connection 28 12 AWG wire TIMING Trigger Strobes tDelay On Ti...

Страница 24: ...Delay 100 µsec min 10 0 seconds max On Time 100 µsec min 10 0 seconds max Off Time 0 Response Time trigger to tDelay 10 µsec typical Burst Mode no delay Pulses 2 min 10000 max Delay 0 On Time 500 µsec min 10 0 seconds max Off Time 500 µsec min 10 0 seconds max Response Time trigger to On Time 1 660 µsec typical Burst Mode with initial delay Pulses 2 min 10000 max Delay 100 µsec min 10 0 seconds ma...

Страница 25: ...ure correct IP address was added to the Monster Brain Controller refer to pages 9 10 Ensure lights on Ethernet port are both lit on both the Monster Brain Controller and PC if applicable Crossover cable must be used to directly connect Monster Brain Controller to PC otherwise use standard cable to connect to Ethernet switch hub Error LED is on The Monster Brain controller hasn t finished is curren...

Отзывы: