![Spectronik PROTIUM-1500 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/spectronik/protium-1500/protium-1500_user-manual_1344204017.webp)
Message
Meaning
Fan PWM auto
Cooling fans control is in auto mode
Blower auto
Oxidant blower control is in auto mode
Mileage
Cumulative Watt-Hour of the system
Shutdown initiated
Entering “Normal Shutdown Phase”
Abnormal Shutdown initiated
Entering “Abnormal Shutdown Phase” due to an error
System off
System is turned off and ready to restart at the next command
Other messages:
Phase
Blink % (at 1Hz)
Meaning
Power ON
10%
5s after start-up power is provided into the fuel
cell controller, LED will blink at 10%, indicating
that the system is ready to receive its “start”
command
Starting Phase
40%
Executing “Starting Phase” procedures
Running Phase
100%
System in normal “Running Phase”
Running Phase
80%
System warning during “Running Phase”
After shutdown
60%
System off due to normal shutdown and on
standby for the next “start” command
After shutdown
0%
System off due to abnormal shutdown
LED status:
CHAPTER 4 | SYSTEM MONITORING & PROTECTIONS