![Spectronik PROTIUM-1500 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/spectronik/protium-1500/protium-1500_user-manual_1344204012.webp)
1. Turn ON your load and draw power as per normal.
Caution: never pull the fuel cell voltage below 27V or
draw power beyond 1500W.
If hybrid battery is connected at the load, PROTIUM-1500 will provide up to its maximum rated output and
the rest is augmented by the battery. The total power available depends on the capacity of the battery.
3.3 POWERING YOUR LOAD WITH PROTIUM-1500
CHAPTER 3 | OPERATING PROCEDURES
2. During Running Phase, the following live status of the fuel cell can be monitored from the GUI.
Mode
Range
Ramp-rate
Constant Voltage Load
Open circuit voltage to 27VDC min or 1500W max
-1VDC/second
Constant Current Load
0A to 55A or 1000W max
+2A/second
Constant Power Load
0W to 1500W max
+150W/second
Parameters
Description
FCV
FC voltage (V)
FCA
FC current (A)
FCW
FC power (W)
Energy
Energy delivered by the fuel cell during this operation (Wh)
FCT1
FC temperature at location 1 (˚C)
FCT2
FC temperature at location 2 (˚C)
FAN
Cooling fan duty cycle (%)
BLW
Oxidant blower duty cycle (%)
H2P1
H
2
supply pressure (Barg)
H2P2
H
2
pressure in FC (Barg)
Tank-P*
Gas tank pressure (Barg)
Tank-T*
Gas tank temperature (˚C)
DCDCV*
Converter voltage (V)
DCDCA*
Converter current (A)
DCDCW*
Converter power (W)
BattV
External power supply voltage (V)
*with purchase of optional Spectronik accessories (gas tank, pressure regulator and DC/DC converter)