![Spectronik CEREBRAL-55 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/spectronik/cerebral-55/cerebral-55_user-manual_1344205017.webp)
3.7 SYSTEM INTEGRATIONS
When integrating with another source of power in parallel to the converter output,
A
Diode
at the converter output must be in place.
*And depending on the type and function of the parallel source, it may require a diode as well.
P_out
Aux_P_out
Source
CEREBRAL-55
Aux Source
LOAD
Diode
With Parallel Power Source(s)
Requirement:
70V, 60A
(4200W)
Voltage-drop:
-0.3V
Output setting:
V_set = 70.3V
I_set = 60A
Counter V drop
= 70V + 0.3V
= 70.3V, 60A
( = 4218W)
LOAD
Diode
Assume 96%
efficient.
Required Input W
= 4218/96%
( = 4394W)
CEREBRAL-55
Obligation:
(>4394W)
Source
Work backwards to determine power requirements and obligations on respective segments.
An example:
Sizing up Power Requirements in an Integration
Stand-Alone Power Source
If the load is capable of generating a potential,
A
Diode
at the converter output must be in place.
P_out
Source
CEREBRAL-55
LOAD
Diode
Recommended Diode
Peak Reverse Voltage: 170V
Max Forward Current: 100A
Reference diode model: STPS200170
CHAPTER 3 | OPERATING CEREBRAL-55
Содержание CEREBRAL-55
Страница 1: ...CEREBRAL 55 SMART DC DC CONVERTER USER GUIDE VERSION 1 0 JUNE 2022 ...
Страница 7: ...Live data logging is available and will be saved in a CSV format CHAPTER 2 OVERVIEW ...
Страница 18: ...CHAPTER 4 MECHANICAL DRAWINGS 4 MECHANICAL DRAWINGS 4 1 MECHANICAL DRAWINGS CEREBRAL 55 ...
Страница 28: ...Files will be saved on desktop To terminate data logging click on the Save again CHAPTER 5 APPENDIX ...