![Spectronik CEREBRAL-55 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/spectronik/cerebral-55/cerebral-55_user-manual_1344205016.webp)
VI Characteristic
of Input & Output relations Graph
Efficiency
reference Table
3.6 PERFORMANCE GRAPHS & TABLES
CHAPTER 3 | OPERATING CEREBRAL-55
Increase Current Limit
Increase Voltage Setting
V_in
V_set
V_out
I_in
I_out
P_in
P_out
Effi
Notes
15
24
24.04
71.80
40.99
1077.00
985.40
91.49
Low-low buck
24
15
15.00
50.70
74.49
1216.80
1117.35
91.83
Low-low boost
24
48
47.68
75.10
35.39
1802.40
1687.40
93.62
Low-mid boost
48
24
23.81
38.90
73.99
1867.20
1761.70
94.35
Mid-low buck
48
48
47.19
75.00
73.29
3600.00
3458.56
96.07
Mid-mid buck/boost
15
90
89.60
75.40
10.89
1131.00
975.74
86.27
Low-high boost
90
15
15.05
14.00
73.99
1260.00
1113.55
88.38
High-low buck
48
80
79.10
75.50
43.99
3624.00
3479.61
96.02
Mid-high boost
80
48
47.14
45.30
73.99
3624.00
3487.89
96.24
High-mid buck
80
80
78.50
67.30
66.99
5384.00
5258.72
97.67
High-high buck/boost
Startup Duration
Graph
t
V
V_in
V_out & I_out
max output
Switch = On
1200ms
Boot-up
500ms
Содержание CEREBRAL-55
Страница 1: ...CEREBRAL 55 SMART DC DC CONVERTER USER GUIDE VERSION 1 0 JUNE 2022 ...
Страница 7: ...Live data logging is available and will be saved in a CSV format CHAPTER 2 OVERVIEW ...
Страница 18: ...CHAPTER 4 MECHANICAL DRAWINGS 4 MECHANICAL DRAWINGS 4 1 MECHANICAL DRAWINGS CEREBRAL 55 ...
Страница 28: ...Files will be saved on desktop To terminate data logging click on the Save again CHAPTER 5 APPENDIX ...